background image

Warning: Do not cover the unit or obstruct the grill area. If covered there is a risk of fire.

G

Do not use the heater in the presence of combustible 
material.

G

When the unit is switched off using the 

‘on/off’

switch, the

fan will continue to run for about 30 seconds to allow the 
element to cool before stopping.

G

The remote control must be fitted with 2 AAA batteries.

Caution: In order to avoid a hazard this 
appliance must not be supplied through an 
external switching device such as a timer or 
connected to a circuit that is regularly switched
on and off by the utility.

Remote Control

Functions:

On/Off

Switches the unit on and off.

Mode

Switches the unit between 1000W, 2000W and 
fan only.

Swing

Switches the oscillating outlet vanes on and off.

Timer

The run time can be adjusted in ½ hour increments
up to a maximum of 7½ hours. The duration of time
selected is indicated by the front panel lights.

‘+’ & ‘-’

Enables the room set point temperature to be 
adjusted. When the room temperature reaches the set
point temperature, the heater will stop heating. When
the room temperature drops 3°C below the set point,
heating will resume. The fan will remain running at all 
times.

5.0  Operating Instructions

Operation

Ensure that the electricity supply is switched on.

Heating

Switch on the unit using the 

‘On/Off’

button. The fan LED will be

illuminated RED (standby) with no operation of the unit.

Use the 

‘Mode’

button to cycle the unit through the different 

operating modes, Off, Fan only, 1kW, 2kW, 2kW with louver
swing and finally back to standby. 

The relevant indicator will be illuminated to show the mode that
is selected. 

Before going back to standby the fan will continue to run for 
approximately 30 seconds to cool the element before the 
louvers close and the fan stops. 

During the cooling period the fan LED will flash green, then 
return to red when the unit returns to standby. 

Timer

Pressing the 

‘Time’

button at any point during the run mode will

cause the timer function to be activated. 

Time periods from ½ hour up to a maximum of 7½ hours run
time can be selected.

As the 

‘Time’

button is pressed the time LED’s will illuminate 

indicating the duration of the time selected.

At the end of the time period selected the unit will return to
standby.

It is not possible to alter the room set point temperature from
the unit controls.

HI-LINE RC E

On/Off

Mode

Swing

Timer

+

-

Cancel

6.0  Wiring Diagram

7.0  Maintenance

M

M

THERMOSTAT

PTC CERAMIC

CONTROL
PANEL

OSCILLATION MOTOR

MAIN MOTOR

OVERHEAT PROTECTION

AC 220V

EXECUTION
PANEL

Isolate the electricity supply.

Maintenance should be restricted to the occasional removal of
dust and lint around the unit.

The outer surface may be wiped over with a damp cloth taking
care to avoid water entering the grille areas.