background image

07

FINESSE EC

FINESSE EC

06

5.0  Installation

5.0  Installation 

(cont...)

l

This product is splash resistant with an IP44
rating. This must be considered when
installing in a location containing a bath or
shower, as defined by BS 7671.

l

The radiator may be positioned in zone 2 
(figure 4) of the bathroom, in so far as no 
operating controls (button, switch, etc.) are 
in reach of persons in the bath or under 
the shower.

FIXING

l

Mark out the distance between the brackets
and the positions for the screw holes as
shown in figure 2 and the dimension tables
at the top of page 7, and ensure the safety
clips are used (see figure 3).

A

B

C

D

H

L

FLOOR

CONNECTION

l

The electrical installation must comply with
local or national regulations.

l

The radiator must be connected to the
electrical supply, using a switched fused
spur with 3mm separation on all poles.

l

If the radiator is installed in a bathroom or
shower room, it must be protected with a
residual current device (RCD) with a rated
residual current not exceeding 30 mA.

l

The radiator should be connected by a
suitable and qualified electrician

C

135

205

D

90

163

Height 

(mm)

300

500

A

160

160

160

160

160

160

160

160

160

160

B

101

203

355

508

660

711

965

1016

1320

1727

400

500

650

800

950

1000

1250

1300

1600

2000

FINESSE EC Double Panel 

(refer to figure 2)

Figure 2.

Figure 3.

Figure 1.

Min.100mm

Min.100mm

Min.100mm

Step 1

Step 2

POSITIONING

l

The radiator must be positioned horizontally,
the right way up on the wall in order for it to
function correctly. Never switch the radiator
on in any other position as this will damage
the electrical element.

l

The radiator must be positioned according
to the applicable standards and the
minimum distances as specified in figure 1
should be carefully observed.

l

The radiator must not be located
underneath an electric socket.

Zone 1

Zone 2

Zone 2

Zone 0

OUTSIDE ZONES

3m

2.25m

0.6m

0.6m

Figure 4.

Safety Clip-on Brackets

6.0  Operating Instructions

The On/Off button (see page 5) is located at
the bottom of the control side of the radiator.

The radiator should only be switched “on”
when it is correctly installed and secured to 
the wall brackets. 

7.0  Technical Characteristics

-10°C + 50°C

Class 1 – IP44

230 VAC – 50 Hz

l

EN 60335-1

l

EN 60335-2-30

l

EN 60529

l

LV Directive 2006/95/EC

l

RoHS Directive 2002/95/EC

Operating temperature

Electrical protection

Power supply

The radiator has been designed to
comply with the following Directives 
and Standards.

8.0  Warranty

The product is covered by a 10 year warranty
except for the electrical and electronic
components that are covered by a 2 year
warranty.

Length 

(mm)

31018 Finesse Instalation Manual A5V2.qxp  13/03/2017  14:39  Page 7