Diagrams in the Fig. 7, 9 ensure operation of fans, equipped
with built-in switch. Diagrams in the Fig. 8, 10 show connection
of fans without built-in switch. Outer switch S is shown.
Fan switch off delay time is adjustable within the range of ap-
prox. 2 to 30 minutes. Time can be regulated by potentiometer
T. Delay increase direction is clockwise, and delay decrease is
anticlockwise). Fans supplied with timer and humidity relay are
turning on by certain humidity level. (50-90%) and are regulated
by potentiometer H by rotaiton clockwise to increase and antic-
lockwise to decrease level during the time, adjusted by timer.
Fans with timer and movement sensor switch on ventilator
when a person moves at a distance from 1 to 4 meters with
viewing angle of the sensor of 100º across and automatically
switch off the ventilator in time, set by the timer from 2 to 30
minutes (by turning the T regulator clockwise for increase and
counterclockwise for decrease of the delay time).
Attention!
Diagram of timer is situated under circuit potential. It is forbid-
den to regulate timer’s delay time unless fan is switched off the
mains. Diagram in Fig. 10 shows connection of lighting lamp to
fan’s timer controlled by single switch (S is an outer switch).
When lightning lamp is off, fan works during the time, adjusted
by timer.
7
8
9
10
7. M 100/125 V & TP, MA 100/125 V
Power supply feed circuit for fans with built-in switch.
8. M 100/125, MA 100/125
Connection of fan without built-in switch to circuit
where S is switch installed additionally.
9. M 100/125 VTH, MA 100/125 VT & VTH
Fan equipped with timer / timer with humidity relay
and built-in switch.
10. M 100/125 T & TH, MA 100/125 T & TH
Fan equipped with timer / timer with humidity relay
and wthout built-in switch.