Thank you for selecting the Myron L

®

 Company Ultrapen™ PT6 Nitrate Pen. This instrument is designed to be accurate, fast, 

and simple to use in diverse water quality applications. Advanced features include: 

 

Selectable Units for Displaying Nitrate Concentration in ppm as Nitrogen (NO

3

-

-N), or Nitrate (NO

3

-

), or in millivolt (mV) 

 

1 or 2 point Calibration Options with Choice of 4 Standard Solutions 

 

Proprietary ISE Sensor Design  

 

Built in Double Junction Reference Electrode, No Need for External Reference 

 

Compatible with EPA Approved Standard Method 4500-NO

3

-

 D 

 

Live or Hold Mode – User Selectable 

 

Auto-Off feature – User Adjustable 

 

Rugged Design with Aircraft Aluminum Body 

 

Durable, Epoxy Encapsulated Electronics 

 

Waterproof  

CONTENTS INCLUDE: 

1.

 

Ultrapen™ Pocket Tester Model PT6 

2.

 

User Replaceable Nitrate Sensor – Installed  

3.

 

100 ppm NO

3

-

-N Standard Solution, 2 oz. 

4.

 

Ionic Strength Adjuster (ISA), 2 oz. 

5.

 

Graduated Cylinder with Cap, 2 ea. 

6.

 

100 

µ

L Pipette with Tip 

7.

 

Protective Cap 

8.

 

Pocket Clip 

9.

 

Lanyard 

10.

 

One N Type Battery – Installed  

QUICK REFERENCE INSTRUCTIONS 

 

1. Press and release the push button to turn the PT6 ON.  
2. While the LED flashes rapidly: Dip the pen in prepared sample solution so the sensor is totally submerged.  
3. Swirl the pen to remove any bubbles that may be trapped in the sensor.  
4. While the LED flashes slowly: Hold the pen steady in the sample solution, keeping the sensor submerged.  
5.  In  HOLD  mode  –  Real  time  readings  are  displayed  until  the  LED  turns  solid  ON.  The  display  holds  the  final 

reading briefly then the PT6 turns OFF. 

6. In LIVE Mode – The PT6 will display constant, real-time measurements for up to 5 minutes then turn OFF. 

 

ULTRAPEN FEATURES 

1.

 

PUSH BUTTON

– Turns the PT6 ON, selects 

instrument settings, and initiates calibration.  

2.

 

BATTERY CAP

– Unscrew to access battery for 

replacement.  

3.

 

BATTERY INDICATOR 

– Shows battery charge 

level.

 

4.

 

DISPLAY

– Displays measurements, menu options, 

battery indicator, and firmware revision (during power-
up).  

5.

 

LED INDICATOR LIGHT

– Indicates when to dip 

the PT6 in solution, when the measurement is in 
progress, and when to remove the PT6 once the 
measurement is complete. 

6.

 

NITRATE SENSOR

– Contains the double junction 

reference electrode, and nitrate ion selective electrode. 

7.

 

ISE ELECTRODE

 – Contains the Nitrate ISE membrane. 

8.

 

THERMISTOR

 – Measures temperature of sample solution. 

9.

 

PROTECTIVE CAP

 – Protects sensor and holds solution for conditioning sensor. To remove, wiggle the cap side to side 

while pulling it off.  

 

Use caution not to spill conditioning solution. Verify the sensor remains fully inserted into the PT6. If not, reinstall per 
Nitrate Sensor Replacement Instructions (see MAINTENANCE).  

 

To replace, wiggle the cap side to side while pushing it on.  

10.

 

CAP STOP

 – Shows how far to push the protective cap when putting it on the PT6

.

 

 

DO NOT

 push the protective cap beyond the cap stop as sensor damage may occur. 

10 

Myron L

®

 Company

 – ULTRAPEN™ PT6 – 

Operation Manual 

Nitrate Concentration and Temperature Pen

 

 

Summary of Contents for Ultrapen PT6

Page 1: ...he sensor submerged 5 In HOLD mode Real time readings are displayed until the LED turns solid ON The display holds the final reading briefly then the PT6 turns OFF 6 In LIVE Mode The PT6 will display...

Page 2: ...mV displays millivolts and Temperature ESC 6 Release the push button when desired parameter type is displayed SAVEd will display then the PT6 will power OFF II TEMPERATURE UNIT SELECTION The PT6 allow...

Page 3: ...re in Nitrate NO3 To select the optimal Standard Solutions and to verify calibration see the CONVERSION TABLE below CONVERSION TABLE Standard Solution Value in NO3 N Value in NO3 N1SOL 1 ppm 4 4 ppm N...

Page 4: ...cts an error in the gain slope it will display Error If this happens clean and condition the sensor then verify you are using approved and properly prepared calibration solutions and recalibrate NOTE...

Page 5: ...s hold the sensor steady during measurement In HOLD mode real time readings are displayed until the LED is ON solid In LIVE mode real time readings are displayed until the PT6 turns OFF 90 sec in HOLD...

Page 6: ...y using concentrated standard solutions to increase the nitrate concentration in the sample by a known value optimally double the measured value and then compare the value with the increase in Pen rea...

Page 7: ...LLING THE NITRATE SENSOR Follow the instructions that come with your replacement sensor Only remove replace the Nitrate sensor in a CLEAN and DRY environment To remove the Nitrate sensor 1 Remove the...

Page 8: ...ngs ca gov 1 Accuracy of measuring calibration solutions after Temperature Controlled 2 Point Calibration with one order of concentration difference 2 For extended life of the sensor store the PT6 in...

Reviews: