 ULTRAPEN

PT2

  pH 

& Temperature Pen

PAckAgE coNTENTs:

PT2 Pocket Tester Pen - Battery Installed

• 

Scoop

• 

Soaker Cap

• 

Pocket Clip

• 

Holster

• 

Lanyard

• 

Operating Instructions

• 

S

 AccURATE

      

S

 

RELIABLE

              

S

 

sIMPLE

Professional Water Analysis

Accuracy of ±0.01 pH

Proprietary Sensor Design

1, 2 and 3 Point Calibration

Automatic Temperature Compensation

Temperature Readout

Waterproof

Powered by 1 N Type Battery

(Included)

myronl.com

MADE IN USA

MADE IN USA

Visit our website:   

myronl.com/pt2.htm

ULTRAPEN™ PT3

 

oRP & Temperature

ULTRAPEN™ PT1

 

conductivity, TDs, salinity 

& Temperature

ULTRAPEN™ PT4

 

Free chlorine Equivalent 

(Fc

E

& Temperature

ORIGINAL

EDITED FOR USE

Minimum height 5 mm

[email protected]

www.novatech-usa.com

Tel: (866) 433-6682 

Fax: (866) 433-6684

Tel: (281) 359-8538 

Fax: (281) 359-0084

Summary of Contents for M-6556

Page 1: ... Calibration Automatic Temperature Compensation Temperature Readout Waterproof Powered by 1 N Type Battery Included myronl com MADE IN USA MADE IN USA Visit our website myronl com pt2 htm ULTRAPEN PT3 ORP Temperature ULTRAPEN PT1 Conductivity TDS Salinity Temperature ULTRAPEN PT4 Free Chlorine Equivalent FCE Temperature ORIGINAL EDITED FOR USE Minimum height 5 mm sales novatech usa com www novatec...

Page 2: ...ration of solution 8 Soaker Cap contains pH Sensor Storage Solution to maintain sensor hydration To remove twist the soaker cap while pulling off using caution not to spill the Storage Solution To replace fill the soaker cap half full with storage solution Twist the soaker cap while pushing back on using caution as excess Storage Solution may squirt out CAUTION Fill the soaker cap ONLY half full o...

Page 3: ...ndicate and gives the duration of each signal LED Signal Action Duration Rapid Flashing Dip pen in solution 6 sec Slow Flashing Measurement in process In Live mode the readings are displayed In LIVE mode note measurement values 10 30 sec in Hold mode 60 sec in LIVE mode Solid Light Hold mode only Measurement is complete In Hold mode captured readings are displayed In Hold mode note measurement val...

Page 4: ...an and free of debris B 3 Point Calibration Use pH 7 4 and 10 buffers for 3 point calibration 1 Thoroughly rinse the pen by submerging the sensor in pH 7 buffer rinse solution and swirling it around 2 Push and release the push button to turn the unit on 3 Push and hold the push button The display will alternate between CAL FAC CAL ºCºF TEMP ModE SEL and ESC 4 Release the button when CAL displays T...

Page 5: ...ration points 9 Verify calibration by retesting the calibration solution E Factory Calibration When pH buffers are not available the PT2 can be returned to factory default calibration using the FAC CAL function This will erase any stored wet calibration NOTE default factory calibration resets the electronics only and does NOT take the condition of the sensor into consideration To return your unit ...

Page 6: ...OM 08 13 Specifications pH Temperature Range 0 00 14 00pH 0 71 C 32 160 F Accuracy 0 01pH After Wet Calibration 0 1ºC 0 1ºF Repeatability 0 01pH 0 1ºC 0 1ºF Resolution 0 01pH 0 1ºC 0 1ºF Time to Reading Stabilization 10 30 seconds Power Consumption Active Mode 37mA Sleep Mode 2µA Temperature Compensation Automatic to 25ºC Physical Dimensions 17 15cm L x 1 59cm D or 6 75in L x 0 625in D Weight 54g ...