background image

Hygiene Supplies Direct Ltd, Castleford, England WF10 1PR declares that 

the Metal Detector is exclusively manufactured and imported for Mylek.

www.hsdonline.co.uk

Environmental Responsibilities

Meaning of crossed-out wheeled dustbin:
Do not dispose of electrical appliances as unsorted municipal waste,
use separate collection facilities.
Contact your local council for information regarding the collection
systems available.

If electrical appliances are disposed of in landfills or dumps, hazardous
substances can leak into the groundwater and get into the food chain damaging
your health and well-being.
When replacing old appliances with new ones, the retailer is legally obligated to
take back your old appliance for disposal free of charge.

SERVICE WARRANTY

Hygiene Supplies Direct guarantees the product free from defects in materials
and workmanship for a period of 1 year from date of purchase.

Should this unit be operated under conditions other than those recommended, 
at voltages other than the voltage indicated on the unit, or any attempts made to
service or modify the unit, then the warranty will be rendered void. The product
you buy may sometimes differ slightly from illustrations. This warranty is in
addition to, and does not affect, your statutory rights. 

If you have any problems with this product, please call our Help Desk 
on 

0800 091 3171

or email 

[email protected]

MYMD1061_Manual  19/7/16  13:02  Page 12

Summary of Contents for MYMD1061

Page 1: ...User Manual Please read and retain for future reference www hsdonline co uk METAL DETECTOR MYMD1061 MYMD1061_Manual 19 7 16 13 02 Page 1...

Page 2: ...oblems please contact our Customer Services on 0800 091 3171 Contents 1 Introduction 2 Safety instructions 3 Manual 4 Metal Detector 5 Plastic Shovel 6 Earphones 7 Environmental Responsibilities 8 War...

Page 3: ...Your metal detector requires six AA alkaline batteries not supplied Treasure Hunter s Code of Ethics All treasure hunters might be judged by the example you set Here are a few basic rules you should f...

Page 4: ...atteries to power your detector not supplied CAUTION Use only fresh batteries of the required size and recommended type Do not mix old and new batteries different types of batteries standard alkaline...

Page 5: ...plugging in the earphones Carefully adjust the volume to a comfortable level Do not listen at extremely high volume levels Once you set the volume do not increase it Over time your ears adapt to the v...

Page 6: ...E DETECTOR Hold the detector in a comfortable position and then rotate VOLUME away from OFF to the desired sound level TUNING THE DETECTOR 1 Rotate VOLUME to the 11 o clock position 2 Set DISCRIMINATI...

Page 7: ...TION to its midpoint 5 Hold down the RED button on the handle until the pointer on the view meter rests at or near 0 then release the RED button 6 Move a sample of the material you want the detector t...

Page 8: ...end of a sweep causes false readings See below for correct sweep technique Sweep slowly hurrying makes you miss targets When the detector detects a ferrous metal sound becomes lower or even disappears...

Page 9: ...tects discriminated metal Non discriminated metal will cause the sound to be higher and the pointer will move to the right NOTE Each time you use the detector in a different area you must adjust the D...

Page 10: ...orward away from you and straight back towards you a couple of times Make a visual note of the exact spot on the ground where the detector beeps 3 Repeat Steps 1 2 at a right angle to the original sea...

Page 11: ...angles See pinpointing a Target If the detector does not display the same signal each time the target is probably heavily oxidised metal The display does not show There might be more than one target...

Page 12: ...old appliances with new ones the retailer is legally obligated to take back your old appliance for disposal free of charge SERVICE WARRANTY Hygiene Supplies Direct guarantees the product free from de...

Reviews: