MYERS ME45AC-11 Installation And Operation Manual Download Page 10

10

  

MY1066 (02-10-20)

WARRANTY

Limited Warranty

Myers

®

 warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from 

defects in material and workmanship for the Warranty Period shown below. 

Product

Warranty Period 

whichever occurs first:

Jet pumps, small centrifugal pumps, submersible pumps and 

related accessories

12 months from date of original installation, 

or 18 months from date of manufacture

Fibrewound Tanks

5 years from date of original installation

Steel Pressure Tanks

5 years from date of original installation

Sump/Sewage/Effluent Products

12 months from date of original installation, 

or 36 months from date of manufacture

Battery Backup Units

MBSP-2, MBSP-2C 

MBSP-3, MBSP-3C

12 months from date of original installation, 

or 18 months from date of manufacture
24 months from date of original installation, 

or 30 months from date of manufacture

Wastewater Solids Handling Pumps

12 months from date of shipment from factory 

or 18 months from date of manufacture 

Our warranty applies only where such products are used in compliance with the requirements of the applicable product catalog 

and/or manuals. For additional information, please refer to the applicable standard limited warranty featured in the product 

manual.
Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper 

installation, or improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power 

through a phase converter will void the warranty. Note also that three phase motors must be protected by three-leg, ambient 

compensated, extra-quick trip overload relays of the recommended size or the warranty is void.
Your only remedy, and MYERS’s only duty, is that MYERS repair or replace defective products (at MYERS’s choice). You must pay all 

labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon 

as a problem is discovered. No request for service will be accepted if received after the Warranty Period has expired. This warranty 

is not transferable.
MYERS SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, 

INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR 

PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an 

implied warranty, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You 

may also have other rights which vary from state to state.

This Limited Warranty is effective April 1, 2014 and replaces all undated warranties and warranties dated before April 1, 2014.

F.E. MYERS 

293 Wright Street, Delavan, WI  53115 

Phone: 888-987-8677 • Fax: 800-426-9446 • www.femyers.com

In Canada: 490 Pinebush Road, Unit 4, Cambridge, Ontario N1T 0A5 

Phone: 800-363-7867 • Fax: 888-606-5484

Summary of Contents for ME45AC-11

Page 1: ...pentair com MY1066 02 10 20 2020 All Rights Reserved INSTALLATIONAND OPERATIONMANUAL SUBMERSIBLE EFFLUENT PUMPS ME45MC 11 ME45AC 11 ME45MC 21 ME45AC 21 MYERS 5937 0109 5937 0109 ...

Page 2: ...2 MY1066 02 10 20 TABLEOFCONTENTS SECTION PAGE Safety Information 3 General Information 4 Installation 5 Operation Maintenance 6 7 Parts List 8 Troubleshooting 9 Warranty 10 ...

Page 3: ...iring to a system control connect ground lead to the system ground Be sure that construction and access to septic sumps conform with all OSHA requirements Do not run the pump dry Dry running can overheat the pump causing burns to anyone handling it and will void the warranty The pump normally runs hot To avoid burns when servicing pump allow it to cool for 20 minutes after shutdown before handling...

Page 4: ...low Motor Duty Continious Discharge Adapter 2 NPT GENERAL INFORMATION MODEL MOTOR HP PHASE VOLTS CORD LENGTH MOTOR FULL LOAD AMPS INDIVIDUAL BRANCH CIRCUIT REQUIRED SWITCH ME45MC 11 1 2 1 115 20 6 1 M 8 6 15 0 Manual ME45MC 11 30 1 2 1 115 30 9 1 8 6 15 0 Manual ME45MC 11 50 1 2 1 115 50 15 2 8 6 15 0 Manual ME45AC 11 1 2 1 115 20 6 1 8 6 15 0 Piggyback Tethered ME45MC 21 1 2 1 230 20 6 1 4 3 15 0...

Page 5: ...eck valve should be a free flow valve that will easily pass solids Be sure check valve installation complies with local codes ELECTRICAL INSTALLATION For automatic operation plug or wire the pump into an automatic float switch or duplex controller The pump will run continuously when plugged directly into an electrical outlet Connect or wire pump to its own individual branch circuit with no other o...

Page 6: ... rubber or plastic gloves when handling the pump for service 2 Place the pump in an area where it can be cleaned thoroughly 3 Remove all scale and deposits on the pump 4 Submerge the complete pump in a disinfectant solution chlorine bleach for at least one hour before disassembling the pump 5 The pump motor housing contains a special lubricating oil which should be kept clean and free of water at ...

Page 7: ...mpeller 3 Reattach the motor leads to the cord leads 4 Reassemble the motor cover motor and seal plate and volute 5 Fill the pump with about 1 2 gallon of clean dielectric oil Part No U197 8A Be sure the oil level is 1 4 above the top of the motor Allow air space for expansion when the motor warms up 6 Replace the oil fill plug The pump is ready for service CHECK PUMP GROUND 1 Set the meter to Rx1...

Page 8: ... DESCRIPTION QTY ME45MC 11 ME45MC 11 30 ME45MC 11 50 ME45AC 11 ME45MC 21 ME45MC 21 50 ME45AC 21 1 Cord 115V 20 6 1m 1 P117 1510 P117 1510 1 Cord 230V 20 6 1m 1 P117 1511 P117 1511 1 Cord 115V 30 9 1m 1 P117 1512 1 Cord 115V 50 15 2m 1 P117 1513 P117 1513 2 Tethered Float Switch 1 139670207 139670257 ...

Page 9: ...loat switch is caught up on something inlet pipe is plugged outlet pipe is plugged 7 Motor windings may be open Take unit to authorized service center Pump fails to empty sump 1 Be sure all valves in discharge pipe are fully open 2 Clean out discharge pipe and check valve 3 Check for blockage in pump inlet or impeller 4 Pump not sized properly A higher capacity pump may be require Pump will not sh...

Page 10: ...ree phase motor with single phase power through a phase converter will void the warranty Note also that three phase motors must be protected by three leg ambient compensated extra quick trip overload relays of the recommended size or the warranty is void Your only remedy and MYERS s only duty is that MYERS repair or replace defective products at MYERS s choice You must pay all labor and shipping c...

Page 11: ...11 MY1066 02 10 20 NOTES ...

Page 12: ...ered and unregistered trademarks and logos are the property of their respective owners Because we are continuously improving our products and services Pentair reserves the right to change specifications without prior notice Pentair is an equal opportunity employer MY1066 02 10 20 2020 Pentair All Rights Reserved 293 WRIGHT STREET DELAVAN WI 53115 PH 866 973 6835 ORDERS FAX 800 321 8793 PENTAIR COM...

Reviews: