SYMPTOM

POSSIBLE CAUSE(S)

CORRECTIVE ACTION

Pump won’t  

1. Blown fuse.

1. If blown, replace with fuse of proper size. 

start or run.

2. Low line voltage. 

2. If voltage under recommended minimum, check 

size of wiring from main switch on property. If OK,
contact power company or hydro authority.

3. Defective motor.

3. Replace pump.

4. Defective float switch.

4. Replace switch.

5. Impeller.

5. If impeller won’t turn, locate source of binding and 

clean out with hose or remove.

6. Float obstructed.

6. Remove obstruction.

Pump starts and   

1. Backflow of water from piping. 

1. Install or replace check valve. 

stops too often.

2. Faulty float switch. 

2. Replace switch.

Pump will not  

1. Defective float switch. 

1. Replace switch. 

shut off.

2. Restricted discharge 

(obstacle in piping).

2. Remove pump and clean pump and piping.

3. Float obstructed.

3. Remove obstruction.

Pump operates but  

1. Low line voltage.

1. If voltage under recommended minimum, check 

delivers little or

size of wiring from main switch on property. If OK, 

no water.

contact power company or hydro authority. 

2. Something caught in impeller. 

2. Clean out impeller or replace pump.

3. Worn or defective parts or 

3. Clean impeller if plugged; otherwise replace pump.

plugged impeller.

4. Airlock (check valve installed  

4. Drill a 1/16" - 1/8" dia. hole between pump

without vent hole).

discharge & check valve.

NOTE:

This pump has no serviceable parts inside case. Opening

case will ruin pump. If obstructions or blockages of impeller can-
not be cleaned out from the outside (for instance, by washing out
with a garden hose), replace pump.

Hazardous voltage; can shock, burn, or kill.

Unplug pump before attempting to clean or work on pump.

MYERS LIMITED WARRANTY

During the time periods and subject to the conditions hereinafter set forth, F.E. Myers will repair or replace to the original user or consumer any portion of your

new MYERS product which proves defective due to defective 

materials or workmanship of MYERS.  Contact your nearest Authorized MYERS Dealer for warranty service. At all times MYERS shall have and possess the sole

right  and option to determine whether to repair or replace defective equipment, parts, or components. Damage due to lightning or conditions beyond the con-

trol of MYERS is NOT COVERED BY THIS WARRANTY. 

WARRANTY PERIOD 

Pumps: 12 months from date of installation or 18 months from date of manufacture. 
Tanks: 5 years from date of purchase.
Labor, etc. Costs: MYERS shall IN NO EVENT be responsible or liable for the cost of field labor or other charges incurred by any customer in removing and/or
re-affixing any MYERS product, part or component thereof. 
THIS WARRANTY WILL NOT APPLY: (a) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with
printed instructions provided; (b) to failures resulting from abuse, accident or negligence; (c) to normal maintenance services and the parts used in connection
with such service; (d) to units which are not installed in accordance with applicable local codes, ordinances and good trade practices; or (e) unit is used for pur-
poses other than for what it was designed and manufactured, and (f) if three-phase submersible motors are installed on a single-phase power supply using a
phase converter or if three-phase power is supplied by only two transformers, making an open Delta system. 
RETURN OR REPLACED COMPONENTS: Any item to be replaced under this Warranty must be returned to MYERS in Ashland, Ohio, or such other place as
MYERS may designate, freight prepaid. 
PRODUCT IMPROVEMENTS: MYERS reserves the right to change or improve its products or any portions thereof without being obligated to provide such a
change or improvement for units sold and/or shipped prior to such a change or improvement. 
WARRANTY EXCLUSIONS: MYERS SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR-
POSE AFTER THE TERMINATION OF THE WARRANTY PERIOD SET FORTH HEREIN. 
Some states do not permit some or all of the above warranty limitations and, therefore, such limitations may not apply to you.  No warranties or representations
at any time made by any representative of MYERS shall vary or expand the provisions hereof. 
LIABILITY LIMITATION: IN NO EVENT SHALL MYERS BE LIABLE OR RESPONSIBLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES RESULT-
ING FROM OR RELATED IN ANY MANNER TO ANY MYERS PRODUCT OR PARTS THEREOF. PERSONAL INJURY AND/OR PROPERTY DAMAGE MAY
RESULT FROM IMPROPER INSTALLATION. MYERS DISCLAIMS ALL LIABILITY, INCLUDING LIABILITY UNDER THIS 
WARRANTY, FOR IMPROPER INSTALLATION–MYERS RECOMMENDS FOLLOWING THE INSTRUCTIONS IN THE INSTALLATION MANUAL. WHEN IN
DOUBT, CONSULT  A PROFESSIONAL. 
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. 
This Warranty gives you specific legal rights and you may also have other rights which vary from state to state. 
In the absence of suitable proof of the purchase date, the effective date of this Warranty will be based upon the date of manufacture. 
DETERMINATION OF UNIT DATE OF MANUFACTURE: Submersible Sump Pump (8-95) month and year stamped on pump nameplate; Column Sump Pump
month and year on red warranty tag.

MYERS

1101 Myers Parkway, Ashland, Ohio 44805-1989

Phone: 419-289-1144 • Fax: 419-289-6658 • www.femyers.com

Summary of Contents for DS33P1

Page 1: ...05 253P7100 3 17 05 1101 Myers Parkway Ashland OH 44805 Phone 1 419 289 1144 Fax 1 419 289 6658 Web Site http www myerspump com DS33P1 DS50P1 DS75P1 Installation Operation Parts For further operating installation or maintenance assistance Call 1 419 289 1144 ...

Page 2: ...ds Disconnect power before servicing Release all pressure within system before servicing any component Drain all water from system before servicing Secure discharge line before starting pump An unsecured dis charge line will whip possibly causing personal injury and or property damage Check hoses for weak or worn condition before each use mak ing certain that all connections are secure Periodicall...

Page 3: ...7 Power Supply Pump is designed for 115 V 60 Hz opera tion and requires a minimum 15 amp dedicated circuit Both pump and switch are supplied with 3 wire cord sets with grounding type plugs For automatic operation switch plug is inserted directly into outlet and pump plug inserts into oppo site end of switch plug For manual operation pump plug is inserted directly into outlet 1 Lake Chemical Co Chi...

Page 4: ...uct part or component thereof THIS WARRANTY WILL NOT APPLY a to defects or malfunctions resulting from failure to properly install operate or maintain the unit in accordance with printed instructions provided b to failures resulting from abuse accident or negligence c to normal maintenance services and the parts used in connection with such service d to units which are not installed in accordance ...

Reviews: