background image

Myers Power Products                        

 

 

6/2013 

CTFRP Series Manual  

 

 

 

CTFRP Series  

Power Supplies 

 

Ferroresonant Non-Standby Power Supplies  

User Manual 

 

Summary of Contents for CTFRP9003

Page 1: ...Myers Power Products 6 2013 CTFRP Series Manual CTFRP Series Power Supplies Ferroresonant Non Standby Power Supplies User Manual ...

Page 2: ......

Page 3: ...onnected Servicing this equipment may require working with protective covers removed and utility power connected Use extreme caution during these procedures High current through conductive materials could cause severe burns When grounding cannot be verified disconnect the equipment from the utility power outlet before installing or connecting to other equipment Reconnect the power cord only after ...

Page 4: ...pply In 120VAC 60Hz Out 60 75 87V 18Amps Specifications Environmental Specifications OPERATING TEMPERATURE 40º F to 158º F 40º C to 70º C HUMIDITY 5 to 95 noncondensing within enclosure Physical Specifications CHARACTERISTIC SPECIFICATION Height 11 5 Width 9 5 Depth 7 5 Weight CTFRP9003 35 lbs Weight CTFRP9006 41 lbs Weight CTFRP9015 50 lbs Weight CTFRP9018 60 lbs Electrical Specifications CHARACT...

Page 5: ...e CTFRP ensure that the input AC utility circuit breaker is OFF Failure to adhere to this warning may result in death serious injury or equipment damage When positioning the CTFRP ensure adequate space for proper airflow Myers recommends that there be at least 3 inches of clearance on all sides and above the module Failure to adhere to this warning may result in equipment damage Do not operate thi...

Page 6: ...nd washer Repeat this procedure for the bottom of the bracket 9 Ensure that the power supply enclosure is closed and locked 10 Holding the Power Supply above the bracket slide the unit down the bracket The lip of the bracket must slide under the lip at the top of the Power Supply cabinet 11 Replace the 10 32 Philips screw removed in step 2 above Wiring 1 Unlock the CTFRP enclosure Lift up the fron...

Page 7: ...ccordance with local electrical codes The barrier strip is wired with the hot leg at the top The bottom connector is chassis ground Initial Start up 1 Turn the utility breaker to the ON position 2 Immediately check to see if the Status LED located at the bottom of the unit is illuminated If the LED is not lit turn off the utility breaker and troubleshoot the problem 3 With the Status LED illuminat...

Page 8: ... product is under warranty repairs are free If not there is a repair charge Procedures for servicing or returning products may vary internationally Contact Myers Power Products for country specific instructions 2 Pack the product well preferably in its original packaging Pack the unit properly to avoid damage in transit Never use Styrofoam beads for packaging as the static electricity that is gene...

Page 9: ...r modified in any way This warranty applies only to the original purchaser EXCEPT AS PROVIDED HEREIN MYERS MAKES NO WARRANTIES EXPRESSED OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Some states do not permit limitation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to the purchaser EXCEPT AS PROVIDED A...