Cable Power Enclosure
Model: CTEG8-240MB
Eight Battery Ground Mount Enclosure w Meter Base, 240VAC
Quick Reference Guide
Euro-block
Installing the Power Supply
Place and assemble the cable power supply onto the top internal shelf of the enclosure.
Attach and fasten the Euro-block terminated wire exiting the EIO assembly to the coax cable
EIO
pin connector.
With the enclosure AC breakers OFF, install the AC line cord to the power supply and appropriate
AC outlet on the EIO assembly. Plug the EIO cable that is terminated the large gray connector into
the output of the power supply.
Installing the Batteries
Before installing any batteries, ensure that the battery breaker on the Electronic/Inverter module is OFF.
There are a number of ways to place and connect batteries in this enclosure. A suggested layout is below.
Connect the batteries as shown below. Physical battery placement may differ. Regardless of connection
style, it is recommended that the thermal probe be connected to positive terminal of Battery #2 of String A.
Powering Up the System
Turn on the AC and battery breakers and power up the power supply. Ensure proper power supply operation.
NOTE: This is a “quick reference” only. Detailed instructions are available by contacting a Myers representative.
Myers Power Products Tel: 610-868-3500 Service: 610-868-5400 Toll Free: 800-526-5088 January-2008 Page 2
Doc# 114537