6. TROUBLESHOOTING

 WARNING

All the maintenance work listed below must be carried out with the power switched off, i.e.
with the plug removed.

PROBLEM

CAUSE

Execution

SOLUTION

Motor switches off 
during operation

Overheating of the fan unit

U

AST

Possible overload (check 
connections and hoses)
Ambient temperature too high 
(room temperature may be a 
max. of 40 °C)
Fan motor defective

Motor doesn’t run

No current to the unit

Switch not switched on

Turbine blocked

Air inlet or outlet blocked

Switch broken off

Wiring loose



U

AST 

AST

Connect device; check fuse. 
Turn on the switch
Eliminate the reason for the 
blockage
Switch off the machine and 
let it cool down; then check 
the connections and hoses
Request a replacement switch 
from the dealer or Preair
Check the wiring and tighten 
if necessary

Motor runs but 
impeller turns 
irregularly or scrapes

Defective rotor or motor

AST

Remove the impeller from 
the housing and then clean or 
repair it

Unit vibrates 
excessively

Accumulation of dirt on the impeller

U

Clean the impeller