Plastic shell dismantling for ABS wall mounted mode

Step one:
Unplug the screw cap on 
the grill

Note:Please do not force these operations over to avoid damage to the buckle

Screw cap

Step two:
Use a Phillips screwdriver 
to twist the screw

Twist the screw

Step three:
pull down the left and right 
buckle on the grille

Left and right buckle

 Step four:
 Open up the grille

Step five:
Use a Phillips screwdriver 
to twist the screw

Twist the screw

Step Six:
Move up the right side of 
the plate

Side plate

Step Seven:
Move left the right side of 
the plate

Step Eight:
Remove the right side of
the plate

Side plate

Side plate

Up

Down

Left 

Right

IV

Installation

DEHUMIDIFIER

2.1.  To get enough air for ventilation of the unit, the installation position should be with good 
         ventilation. 
2.2.  The installation position can hold the outdoor unit without noise and shake.
2.3.  No sunlight to the unit. Set an awning if necessary.
2.4.  The water from rain and defrosting can be discharged in the installation position.
2.5.  The unit will not be covered by snow in the installation position.
2.6.  The discharged air will not face strong air in the installation position.
2.7.  Assure the noise caused by the unit ventilation and operation will not affect the 
        neighbour.
2.8. The installation position will not be affected by garbage, oil and mist.
2.9.  The  unit will be damaged under the condition with oil(engine oil), salt(sea area) 
         and sulfide air(near thermal spring and refining factory).

2.The requirement of installation place

3. Installation requirement

3

.1. The unit can be installed in the balcony, roof, floor or any other convenient place and reliable 

       load-bearing.
3.2.Airiness place.
3.3.No heat radiation or other heat source place
3.4.Should be set up shed against the snow in winter.
3.5.Barrier-free at the air inlet or outlet place.

Summary of Contents for ABS 12A

Page 1: ...DEHUMIDIFIER...

Page 2: ...ed mode The requirement of installation place Installation requirement Hot water pipe connection Electric wiring 1 2 3 Preface Important Safety Instructions Products Principle 4 Principle descdiption...

Page 3: ...t operate in a closed confined space Please keep this manual Note We recommend that any repairs must be professional 2 Products Installed dehumidifiers to reduce humidity in the air the room so people...

Page 4: ...Protect your enviroment Even when you cannot see it moisture in the form of water vapour is all around us held in suspension in the air The relative humidity of the air in many cases determines the ex...

Page 5: ...g e r a n t Compressor Net weight Gross weight Net dimension Packaging dimension A B C MBA Size A B C 2 The dimension for dehumidifier 2 1 ABS wall mounted mode 7A 905 243 673 Units mm 1288 1672 243 2...

Page 6: ...ller in the electrician base box and tighten the two setscrews Illustration 3 Illustration 4 Illustration 1 Illustration 2 Use flat screwdriver to press down the two back off and lift open the face co...

Page 7: ...SET Defrost status M SET M SET Keep flash Keep flash out 5 45 Ambient temperature of the unit can not properly dehumidify 1 The button after on this button you can change the fan speed Parameter quer...

Page 8: ...s to change the setting time press ON OFF button to cancel the timer when finish the timing setting press to confirm exit In the case of the boot you can press the button set the unit off after how ma...

Page 9: ...mode display FAN icon heating mode display HEAT icon dehumidification plus heating mode display AUTO icon eating mode e DEHUMIDIFIER 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 AC N OUT3 OUT2 OUT1 CN...

Page 10: ...position can hold the outdoor unit without noise and shake 2 3 No sunlight to the unit Set an awning if necessary 2 4 The water from rain and defrosting can be discharged in the installation position...

Page 11: ...the machine As shown below Swimming pool Not the corner Swimming pool 3 10 Open the front grille plastic case you can see the plastic plate around the screw open the screw only after about two plasti...

Page 12: ...r construction of plumbing standards 4 3 After hot water pipes connected it must be pipe connection rigorous testing plus 0 7Mpa pressure testing 24 hours system pipes connector no leakage and clean a...

Page 13: ...connection take the unit power line remote control three core lines electric heater power line solar circulated water pump control power line water tank temperature sensing line solar collector temper...

Page 14: ...or solvents may cause local adverse effects and use the tank water leakage occurred 5 6 The long term no use please pull the plug Cleaning the machine please stop and pulled out the power plug otherw...

Page 15: ...when all the mode setting the system meet power failure a orsuddenly meet without tight slide in power the system can automatically stored before the operation state in the next time in power system...

Page 16: ...ng normal or not Detection of the heating water supply system s normal Check the power phase sequence whether misphase Check humidity wire controller connection is normal or not 5flash 1 off 6flash 1...

Page 17: ...oil temp Switch High pressure switch Low pressure switch Electric protection switch LCD LED wire controller Turn on Turn off Compressor R S Blue White Capacitance Capacita nce Grey Yellow Red Fan Oran...

Page 18: ...l switch short circuit turn on cut turn off 1 NOTE Hot water cycle pump effective for the unit with heating coil function 2 WIRING DIAGRAM C Red AC N OUT3 OUT2 OUT1 CN1CN2 CN3 CN4 CN19 OUT4 OUT5 SW1 L...

Page 19: ...ressure switch HP1 LP1 P6 Legend Power phase protection switch Yellow White Red Humidity sensor Yellow WIRING DIA DIAGRAM 2 Infrared remote control switch short circuit turn on cut turn off 1 NOTE Hot...

Reviews: