12. The product used in the lance must be a watery product.
13. Care should be taken to avoid injecting into the mouth and in the nostrils.
14. Clean the small cup and the inner tube hole before and after each use of the lance. Avoid
tube plugging caused by product drying. Cleaning method: Pour pure water into the small cup,
then press the control button down and pull back, and quickly spray the water out of the cup.
15. When sucking blackheads, it is best to put a proper amount of cotton paper inside the glass
tube to prevent dirt from being sucked into the airway tube and damage the main unit. Don't stay
in the face for too long, so as not to cause bruises
16. If there is no suction when starting up, it is normal, and it will return to normal after a while.
The suction size can be adjusted with the metal knob, which is large clockwise.
17. When using the spray bottle, do not insert the catheter into the black hole to prevent the
lotion from being sucked into the air pump and damage the main unit.
18. It is normal for the squeaky sensation of current to flow through the operation of the
ionization operation.
19. When the cleaning shovel is cleaned, the groove is outward. The operation will see the water
droplets splashing in the water, and the skin part of the instrument is not covered with water
drops. Put the cleaning shovel upside down and apply the flat to the skin for import and lifting.
VI Troubleshooting
1. The instrument has not respond ?
A. Check if the instrument socket is plugged in.
B. Check if the handle link is inserted.
C. Check if the instrument has contact products.
2. The instrument does not turn on, and the button light on the back of the instrument does not
light up?
A. Make sure the power cord is connected to a valid power outlet.
B. Is the fuse tube on the back of the instrument loose or burnt?
3. The instrument have no current output?
A. Please check if the instrument handle and the connector connected to the body are tightly
connected.
B. Please check whether the treatment part has been cleaned. The grease or oily essential oil
product may cause the instrument's treatment handle to be in poor contact with the human body,
resulting in no current output.
4. The current output is weakened?
A. Please check if the instrument handle and the connector connected to the body are tightly
connected.
B. Please check if there is any non-conductive grease and other substances on the handle of the
treatment. This will cause the contact to be weak and the output to be weakened.
C. Please check if the product used is the adapter specified by the instrument.
Summary of Contents for SR-MJ1805H
Page 1: ...User Manual SR MJ1805H...