1. Introduction to Manual

1.1 Purpose

This instructions for use manual provides a description of the system components, its

controls and displays, instructions for its operation, and other equipment information
important to the user

Warning: Do Not operate this machine before reading this manual thoroughly. In
addition to this manual,additional clinical training may be available by the company

or your local distributor.
For more information on training available please contact your local representative.

1.2 Conventions

Note: Notes designate information of special interest.

Caution: Cautions alert the user to precautionary steps necessary to properly
operate the system.Failure to observe these cautions may void the warranty

Warning: Warnings alert the user to information that is of the highest importance
and vital to the safety of the patient and user

All procedures are broken down by numbered steps.Steps must be completed in the sequence
they are presented
Bulleted lists indicate general information about a particular function or procedure.They do not
imply a sequential procedure.

Control names are spelled as they are on the system,and they appear in Bold text

2. Contraindication Safety

1. People with heart disease, high blood pressure, or configured cardiac Pacemaker.

2. People with acute inflammation, asthma, deep vein thrombosis, thyroncus, cancer.

3. People with hemorrhagic diseases, trauma or who is bleeding.

4. Pregnant women

5. Medical plastic artificial or metal parts inside the body such as metal teeth or

silicone breast implants.

6. People with abnormal immune system.

7. People with numb or insensitive to heat.

8. If you are feeling unwell, Prohibited in the ears, nose, eye throat and do not use this

device in advance and tell your doctor.

9. Children under 12 years old are not allowed.

Summary of Contents for MS-6651

Page 1: ......

Page 2: ...authorized people in the company It forbids others to change and maintain the machine except the professional people Please contact us if there is any trouble during operation After Sale service We of...

Page 3: ...importance and vital to the safety of the patient and user All procedures are broken down by numbered steps Steps must be completed in the sequence they are presented Bulleted lists indicate general i...

Page 4: ...ctor for help 5 Installment and Use I Working Condition Using at normal temperatures and pressure Please do not stay in too cold too hot too dry and too wet II Technical Parameters Power supply Input...

Page 5: ...W Red Wavelength 650 730 nm IV How to install the accessories A Cooling head Socket B Bipolar 3D RF Socket C Quadrupolar 3D RF Socket D Eightpolar 3D RF Socket E Sextupolar Vacuum 3D Smart RF Socket F...

Page 6: ...ise it will burned machine when you add water remember connect Cooling head with machine Also please clear it dry after you filling water just in case it has water around machine V Program Setting 1 U...

Page 7: ...7 2 Click any place of the screen to enter into the main interface A 40K Cavitation 1 Press button to enter into 40k unoisetion function display as follow...

Page 8: ...ase or decrease the ENERGY 4 Please click to chose working model 5 Please click to start or pause function 6 Please click to come back to the main function interface B Sextupolar Vacuum RF 1 Press but...

Page 9: ...se or decrease the RF ENERGY 4 Please click and to set the time for the suction and release 5 Please click M1 M2 M3 M4 M5 to choose the model 6 Please click to start or pause function 7 Please click t...

Page 10: ...operation display as bellow 2 Please click to set working time 3 Please click to increase or decrease the RF ENERGY 4 Please click to start or pause function 5 Please click to come back to the main f...

Page 11: ...cy operation display 2 Please Click to choose Function of head 3 Please click to set working time 4 Please click to increase or decrease the ENERGY 5 Please click to start or pause function 6 Please c...

Page 12: ...ration display 2 Please click to set working time 3 Please click to increase or decrease the RF ENERGY 4 Please click to start or pause function 5 Please click to come back to the main function interf...

Page 13: ...or pause function 5 Please click to come back to the main function interface About Treatment 1 Abdomen thigh buttock arms slimming Please clean the skin and then put the ultrasound gel on the treatme...

Page 14: ...lease clean the skin and then put the rf gel on the treatment area then turn on the machine set the time and energy pls set the energy from low to high to get the best comfortable temperature then fol...

Page 15: ...ar in lines THIGH Treated time 30 minutes 1 From down to upper pushing to the groin to dredge the lymph 2 From down to upper circling push by anticlockwise can help decomposing fatness 3 Also can push...

Page 16: ...esture pull come and go 3 Along the muscle of arm pull up to lift and tight the muscle BACK Treated time 20 to 30 minutes 1 First by come and go pushing the bladder nerve 2 to 3 times 2 Circling by an...

Page 17: ...17 4 Using lymph drainage gesture pull the toxin to the lymph node can help improving the back curve...

Page 18: ...18...

Page 19: ...RF Probe for Body Sculpture 1 x Quadrupole 3DSMART RF Probe for Arm face small area of body 1 x Bipolar 3D SMART RF Probe for face and eyes 1 x Cooling head 1 x Holder 1 x Power Supply Cord Both 110v...

Page 20: ...lear each handle after one treatment since there has many Gel on head during treatment 2 Please change water every one week 3 Please clear filter once you see dirty thing inside it 4 Conservation meth...

Reviews: