Material: Soft Sewn Fabric
Charging Voltage: DC 12V
Massage Area: LEG, FOOT
Weight: 1.6Kg
Heating Temperature: 49
℃
3. User Contraindications
Some groups of people should be cautious about using this instrument. Please consult a doctor
or a professional before using the instrument. The details are as follows:
1. Women in pregnancy or lactation.
2. People who suffer from “3Hs”(hypertension,hyperglycemia and hyperlipemia), heart diseases
or are equipped with pacemakers.
3. Those who have incisions in their legs or who are recovering from operation.
4. Those who suffer from severe damages to legs.
5. Those who suffer from epilepsy, severe diabetes and hyperthyroidism.
6. People with skin diseases or infectious diseases.
4. Dos and Don’ts
1. The plug with grounding pin must be used before the instrument is used and the power
socket of the instrument is properly grounded.
2. Ensure that the voltage of the instrument is suitable. If the voltage of the local power supply is
not stable, we suggest that the user add a voltage regulator with matching power between the
mains and the instrument.
3. In order to ensure the treatment effect and normal service life of the instrument, please use
the specified parts provided or suggested by the original manufacturer.
4. The instrument should not be placed in damp places or near water sources, and should not be
directly exposed to sunlight.
5. Do not place the instrument near a strong heat source, as this may affect the life and normal
use of the instrument.
6. Before treatment, please remove all metal objects from the body first, so as to avoid
unexpected conditions and influence the curative effect.
7. Patients who are suffering from illness should consult with a doctor and gain permission from
the doctor before use.
8. Please turn off the power switch of the device, and ensure that the total power supply of the
device is turned off before the staff leaves after daily use, so as to ensure the safety of the
electrical products.
9. Make sure the area to be treated is dry before treatment.
10. The massager must be wrapped round legs and feet before treatment and then you can
start it and set mode, temperature and force intensity.
11. Use this machine in strict accordance with instructions in the user manual.
5. Troubleshooting & Solutions
1. The controller doesn’t display any thing?
A. Please check the power cord is connected properly.
B. The controller is broken.
2. The controller can work but the masaager does not have the heat release after temperature
is adjusted?
A. Please check whether this massager have wrapped leg and foot tight.
Summary of Contents for LT-OL703
Page 1: ...User Manual LT OL703...