4. No suction coming from the hydro facial and there’s no nutrients outflow?
A. Please check whether the waste water recovery bottle cap is tight or not, and
whether the nutrient solution bottle is tight or not.
B. Please check whether the button for adjusting suction and nutrient solution stays
on 0.
C. Please check whether the output of nutrient solution is excessive.
5. No spray coming from the hydro spray jet?
A. Please check whether the nozzle is blocked.
B. Please check whether the regulating part of the nozzle tail is tightened.
C. Please check whether the wrench of the spray gun is loose.
6.The instrument can be activated, but the wrong information appears on the screen?
A. Please unplug the power plug behind the instrument and wait about 1 minute
before restarting the instrument.
B. If the above method did not work, please contact the instrument distributor for
assistance.
7. If there is no suction, please check:
A. Whether the rubber inside the cover of the waste bottle is pressed tight.
B. Whether the rubber ring of the connection between the hydro probe and the screw
head is detached.
C. Whether the suction adjustment has been adjusted to the maximum.
D. Whether the machine interior has been cleaned to avoid blockage.
8. If there is no water flow, please check :
A. Whether the solution bottle is installed in place.
B. If it is blocked due to uncleanness. If so, please clean it.
C. Whether the plugs are not well connected.
D. whether the water flow is regulated.
E. Please press the tip of the hydro probe for about 10 seconds, since it will take some
time for the water to flow from the solution bottle to the probe, please be patient and
wait for a while.
6. FAQs
1.Q: Why exfoliate?