CALIBRATION 

When to calibrate - calibration is RARELY required. 

Calibration may be required when the scale is first set up for use, or if the scale is 

moved to a different altitude or gravitation.    This is necessary because the weight 

of a mass in one location is not necessarily the same in another location. Also, with 

time and use, mechanical deviations can occur. 
 

How to calibrate 

**you must have an accurate 100 gram weight or combination of weights in 

order to calibrate** 

 

1.

 

  The scale must be powered OFF

.  Press and hold 

[ZERO]

 first, then Press 

 

[ON/OFF]

 while keeping the 

[ZERO] 

button depressed, then release both keys. 

The display will show the A/D value (a series of random numbers). 

2.

 

Wait for the stable indicator to be displayed, Press 

[UNIT]

 the display will show 

"00SAVE"

, then after 2 seconds the display will return to the random A/D value. 

3.

 

Place 100 grams of weight(s) on platform.  Wait for the stable indicator to 
display, then press 

[UNIT]

, the display will show "00SAVE".  Calibration is 

complete, remove the weight(s).

 

4.

 

Turn the scale OFF (Press the ON/OFF key) , then turn it back ON and check 
some weight readings.    If calibration is still incorrect, repeat calibration but try it 
more slowly.

 

If calibration is repeatedly incorrect then: 1) Replace the batteries,    2) Try a more 
stable surface or vibration and interference free location,    3) Be sure there is no 
static electricity on the scale (use an anti-static spray to remove static electricity) 
 

FEATURES 

z

 

Auto shut off (optional)          

●   

Auto calibration 

z

 

Auto zero tracking                           

●   

Auto backlight (optional) 

z

 

Low battery indication           

● 

g /oz/mg/ozt/dwt/ct/gn/pcs conversion       

z

 

Large LCD (6digits 15 mm high)     

● 

with counting function 

z

 

Large square weighing tray 

z

 

Net weight/stability indication 

z

 

0.005 gram division – professional accuracy 

 
 

PARTS DESCRIPTION 

 

RIGHT SIDE 

         

AC adaptor 
Socket 

 

 TOP 

 

Weighing platform 

The arch face of platform is front.         
Correct the direction of the pan. 

 

 

 

 

Display 

 

ON/OFF

 key 

Turns the scale 

 

power on/off. 

                                                                                                PCS key 

UNIT 

key                                      counting mode 

Changes weighing units, g ,oz,lb, ozt, dwt, ct,gn or pcs(counting mode). 
 

ZERO 

key (for TARE) 

ets display to zero or   
Subtracts weight of a container. 

 

 BOTTOM 

 

Battery compartment 

 

Battery compartment cover     

 

Batteries  

Use 6 AA batteries 

 

DISPLAY  

 

STABLE

 indicator                     Auto backlight function indicator 

Indicates when the reading is stable.       

                                                                                   

Auto shut off function indicator 

                                                                               

                                                                                                                                                                   

ZERO

 indicator 

                                                                              Indicates when the reading is stable

 

Weighing unit

 

   

                                                                         

 

  Low battery indicator

 

 

Summary of Contents for i101

Page 1: ...es and any radio frequency device can cause temporary interference and cause the scale to temporarily not work properly Please do not use any electronic device near the i101 Just like in an Airplane do not use your cell phone near the scale when it is in use While there is NO risk of permanent damage to the scale interference can cause an incorrect calibration or incorrect weight readings i101 COM...

Page 2: ...ight of these samples will show on the display 4 Press the UNIT key several times to put the scale in PCS mode the indicator should be on pcs 5 Select the sample size the same as you chose above by pressing the PCS key press it as many times as necessary to put it in the correct sample size the sample size is the same as in step three 10 20 50or100 6 Press the UNIT key the display will show pass t...

Page 3: ...alibration is still incorrect repeat calibration but try it more slowly If calibration is repeatedly incorrect then 1 Replace the batteries 2 Try a more stable surface or vibration and interference free location 3 Be sure there is no static electricity on the scale use an anti static spray to remove static electricity FEATURES z Auto shut off optional Auto calibration z Auto zero tracking Auto bac...

Page 4: ...re is no cell or cordless phone interference and no vibrations 3 WEIGHING Before weighing Whenever possible please allow the scale to warm up for 30 seconds after first turning the power on so that the scale will function properly and accurately Error messages EEEE Overload Low battery Calibration may be required before weighing Calibration is rarely needed Read CALIBRATION first and if necessary ...

Reviews: