my-PV AC ELWA-F Assembly And Operation Manual Download Page 6

AC ELWA

®

-F Assembly- and Operation Manual, 170224 

 
4.

 

Choose language and correct COM port under Settings Menu 
AC ELWA Software connects automatically with AC ELWA-F. Current data of the device are 
displayed, including AC frequency: 

 

5.

 

Choose „Frequency Control“ in Stettings Menu. 

 

6.

 

Choose desired setting, press OK. Values are stored in non-volatile memory. Readjustment 
is possible anytime. 

 

 

Summary of Contents for AC ELWA-F

Page 1: ...ty 3 5 Mounting and Installation Instructions 3 6 Electrical Connection 4 7 Operation with frequency shift inverters 4 8 Controls and Indicators 4 9 Operating status indicator 5 10 Factory preset 5 11...

Page 2: ...local regulations for mounting and connection Any damage caused by ignoring the installation and user manual is not covered by the manufacturer s warranty Permanent equipotential bonding of the device...

Page 3: ...ted section of the heating rod is 90 mm from sealing face the length of the thread pipe must not exceed 80 mm Use the O ring seal supplied Do not use any grease or lubrication agents The plastic threa...

Page 4: ...000 W It is recommended to set maximum power of the AC ELWA F not more than half the power of the battery inverter The lowest adjustable maximum power limit of the AC ELWA F is 500 watts Corresponding...

Page 5: ...spanner position 3 Plug in device all 3 LEDs are flashing after some seconds to indicate setup mode 4 Turn rotary knob to 13 A setting LEDs run from top to bottom 5 After 5 seconds of no knob turn LED...

Page 6: ...der Settings Menu AC ELWA Software connects automatically with AC ELWA F Current data of the device are displayed including AC frequency 5 Choose Frequency Control in Stettings Menu 6 Choose desired s...

Page 7: ...upply In addition to adjusting the fuse setting the AC ELWA F s maximum power can be reduced to fit to smaller battery inverters My PV recommends to set maximum power of the AC ELWA F not more than ha...

Page 8: ...ternal electronics Device stops and reconnects after cool down 4x flash Hardware fault Unit must be serviced by authorized staff 6x flash Temperature probe fault Unit must be serviced by authorized st...

Page 9: ...ower max 3 000 W at 230 VAC Power control Linear frequency curve Frequency range 47 Hz to 54 Hz Low frequency setting 0 W 49 000 51 900 Hz High frequency setting 49 100 52 000 Hz 0 1 Hz above low freq...

Reviews: