Safety Notice

Alternating Current

Terminal Block

LIVE

GROUND

NEGATIVE

LIVE 

-

 Black

NEGATIVE 

-

 White

GROUND-Housing

LED

 

DrivER

Mains power supply 

Electrical Connections

L

G

N

Input wire H07RN-F 3x1.5mm²  or rubber sheathed cable (not supplied).
Conductor must have a minimum cross-sectional area of 1.5mm² .

STEP I:

 

 

Connect the LINE wire in the mains power supply cord to black LINE

 wire from lightbody via a terminal block.

STEP II: 

Connect the NEUTRAL wire in the mains power supply cord to white 

NEUTRAL wire from lightbody via a terminal block.

STEP III: 

Connect the green grounding wire in the mains power supply cord to

 green grounding wire from lightbody via a terminal block.

***

IF THERE IS JUNCTION BOX IN CEILING:

STEP III: 

Push back the connected wires into junction box.

STEP I:

 

 

Open the lid of the external junction box.

STEP II: 

Connect the LINE wire in the mains power supply cord to the L marked 

hole In the terminal block from the external junction box, and tighten the 
connection properly.

STEP III: 

Connect the NEUTRAL wire in the mains power supply cord to the N 

marked hole in the terminal block from the external junction box, and tighten 
the connection properly.

***

EXTERNAL JUNCTION BOX:

STEP IV: 

Connect the YELLOW/GREEN GROUNDING wire in the mains power 

supply cord to the G marked hole in the terminal block from the external junction
box, and tighten the connection properly.

STEP V:

 

 

Close the junction box, and fasten the screws to fix the lid to the junction 

box body.

This  logo  indicates  that  this  product  must  not  be  disposed  of  with  other  waste.
 Please recycle used lamps to prevent environmental hazard and threats to human 
health resulting from improper disposal.

Common causes and solution

Encountered Problem

Possible Cause

Remedy

Module  does  not  light  up

Internal wire disconnected

Open fixture and locate loose wires, reconnect connectors or wires and close 

cover. And retest.

LED driver failure

Open fixture and check for disconnected wiring.  If all wires are fine, replace LED 

driver with new one and test.

Module Failure

If all the above remedies are trialed then the light module has most likely failed. 

Contact us for replacement and warranty information.

WIRING INSTRUCTION

7

Model

 

No

.

No. of leds

System

 

Wattage

Dimensions

 (

L x W

 

x

 

H

)

Net Weight

Working

 

Environment

IP

MLLG-AX-LED-HM-

450-5000-U

216

485W

622 (24.49" ) x 680 ( 26.77" ) x 112 mm ( 4.41" )

19.96kg(44.00Ibs)

-

40

-+

50

IP67

MLLG-AX-LED-HM-

600-5000-U

288

645W

742 (29.21" ) x 680 ( 26.77" ) x 112 mm ( 4.41" )

23.06kg(50.84Ibs)

MLLG-AX-LED-HM-

750-5000-U

360

802W

922 (36.30" ) x 680 ( 26.77" ) x 112 mm ( 4.41" )

27.5kg(60.63Ibs)

MLLG-AX-LED-HM-

900-5000-U

432

964W

1042 (41.02" ) x 680 ( 26.77" ) x 112 mm ( 4.41" )

30.98kg(68.30Ibs)

         Input

 

Voltage

:

120-277VAC 50/60Hz             

Mounting U&C

Main specifications: