Safety Notice
Alternating Current
Terminal Block
LIVE
GROUND
NEGATIVE
LIVE
-
Black
NEGATIVE
-
White
GROUND-Housing
LED
DrivER
Mains power supply
Electrical Connections
L
G
N
Input wire H07RN-F 3x1.5mm² or rubber sheathed cable (not supplied).
Conductor must have a minimum cross-sectional area of 1.5mm² .
STEP I:
Connect the LINE wire in the mains power supply cord to black LINE
wire from lightbody via a terminal block.
STEP II:
Connect the NEUTRAL wire in the mains power supply cord to white
NEUTRAL wire from lightbody via a terminal block.
STEP III:
Connect the green grounding wire in the mains power supply cord to
green grounding wire from lightbody via a terminal block.
***
IF THERE IS JUNCTION BOX IN CEILING:
STEP III:
Push back the connected wires into junction box.
STEP I:
Open the lid of the external junction box.
STEP II:
Connect the LINE wire in the mains power supply cord to the L marked
hole In the terminal block from the external junction box, and tighten the
connection properly.
STEP III:
Connect the NEUTRAL wire in the mains power supply cord to the N
marked hole in the terminal block from the external junction box, and tighten
the connection properly.
***
EXTERNAL JUNCTION BOX:
STEP IV:
Connect the YELLOW/GREEN GROUNDING wire in the mains power
supply cord to the G marked hole in the terminal block from the external junction
box, and tighten the connection properly.
STEP V:
Close the junction box, and fasten the screws to fix the lid to the junction
box body.
This logo indicates that this product must not be disposed of with other waste.
Please recycle used lamps to prevent environmental hazard and threats to human
health resulting from improper disposal.
Common causes and solution
Encountered Problem
Possible Cause
Remedy
Module does not light up
Internal wire disconnected
Open fixture and locate loose wires, reconnect connectors or wires and close
cover. And retest.
LED driver failure
Open fixture and check for disconnected wiring. If all wires are fine, replace LED
driver with new one and test.
Module Failure
If all the above remedies are trialed then the light module has most likely failed.
Contact us for replacement and warranty information.
WIRING INSTRUCTION
7
Model
No
.
No. of leds
System
Wattage
Dimensions
(
L x W
x
H
)
Net Weight
Working
Environment
IP
MLLG-AX-LED-HM-
450-5000-U
216
485W
622 (24.49" ) x 680 ( 26.77" ) x 112 mm ( 4.41" )
19.96kg(44.00Ibs)
-
40
℃
-+
50
℃
IP67
MLLG-AX-LED-HM-
600-5000-U
288
645W
742 (29.21" ) x 680 ( 26.77" ) x 112 mm ( 4.41" )
23.06kg(50.84Ibs)
MLLG-AX-LED-HM-
750-5000-U
360
802W
922 (36.30" ) x 680 ( 26.77" ) x 112 mm ( 4.41" )
27.5kg(60.63Ibs)
MLLG-AX-LED-HM-
900-5000-U
432
964W
1042 (41.02" ) x 680 ( 26.77" ) x 112 mm ( 4.41" )
30.98kg(68.30Ibs)
Input
Voltage
:
120-277VAC 50/60Hz
Mounting U&C
Main specifications: