The installation must conform with local codes, or in the absence of local codes, to the national fuel gas code, 
ANSI Z223.1 (or latest addenda). The Appliance and its individual shut off valve must be disconnected from the 
gas supply piping system during any pressure testing of that system in excess of ½ PSI (3.45Kpa). 
 
The  appliance  must  be  isolated  from  the  gas  supply  piping  system  by  closing  its  individual  manual  shut  off 
valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ PSI 
(3.45Kpa). 
 
The gas supply line must be at least the same size as the gas inlet of the appliance. 
 

FLEXIBLE COUPLINGS, CONNECTORS AND CASTERS 
 

For an appliance equipped with casters the installation shall be made with a connector that complies with the 
Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or Connectors for Moveable Gas Appliances, 
CAN/CGA-6.16, and a quick 

disconnect device that complies with the standard for Quick Disconnect Devices for Use with Gas Fuel, ANSI 

Z21.41, or Quick Disconnect  Devices for Use  with Gas Fuel, CANI-6.9. Adequate means must  be  provided to 
limit the movement of the appliance without depending on the connector and the quick-disconnect device or 
its associated piping to limit the appliance movement. 
 
Restraining devices may be attached to the back frame/panel of the unit. 

 

OPERATING INSTRUCTIONS

: Before lighting, check all joints in the gas supply line for leaks. 

DO NOT USE OPEN 

FLAME TO CHECK FOR LEAKS! USE SOAP AND WATER SOLUTION. 

Putting an open flame beside a new gas connection is extremely dangerous. 
LIGHTING Initial pilot lighting: 
CAUTION: When lighting pilots  and checking for leaks, do not  Stand with your face  close to the combustion 
chamber. 
All Sierra appliances are adjusted and tested before leaving the factory, effectively matching them to sea level 
conditions. Adjustments and calibrations to assure proper operation may be necessary on installation to meet 
local conditions; low  gas characteristics,  to correct  possible problems caused by rough handling or vibration 
during  shipment,  and  are  to  be  performed  only  by  qualified  service  personnel.  These  adjustments  are  the 
responsibility of the customer and/or dealer and are not covered by our warranty. Before lighting any pilots, 

make sure that burner valves and thermostats are turned “off”.

 

 

A. TOP BURNERS / RAISED GRIDDLE

BROILER / BROILER

. All top section burners are equipped with constant 

burning  pilots.  These  are  to  be  manually  lighted  immediately  after  the  gas  is  turned  on  and  the  system  is 
checked  for  leaks.  Burner  pilots  are  provided  for each  burner  and  can  be  rechecked  for  proper  adjustment. 
Adjustments can be made with a screwdriver to 
the brass pilot valve accessible through the valve cover. 

B. HOT TOP / GRIDDLE.

 The pilot should be lighted immediately after the gas is turned on and the system is 

checked for leaks. The pilot can be reached with a long match through the valve cover, or by lifting the plate 
upward and accessing through the top. 

C. STANDARD OVEN

. Pilot gas is tapped from the main burner manifold pipe, routed through tubing to a pilot 

safety valve, and then to the pilot burner. Gas flow is controlled by the safety valve. 
Oven pilot lighting or relighting is to be completed in the following sequence: 

(1) Turn the oven thermostat knob to “off” and wait 5 minutes.

 

Summary of Contents for Sierra SRSP-18

Page 1: ...L INSTRUCTIONS INSTALLATION OPERATION MAINTENANCE STOCK POT RANGE SRSP 18 READ THIS MANUAL IN IT S ENTIRELY BEFORE USING THIS EQUIPMENT 5659 ROYALMOUNT AVE MONTREAL QC CANADA H4P 2P9 TEL 514 737 9701 1 888 275 4538 ...

Page 2: ...ation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment MISE EN GARDE Une installation un réglege une modification ine réparation ou un entretien inadécuat peut provoquer des dommager matériels des blessures ou la mort Lisez sougneusement les in...

Page 3: ...nit is configured is noted on the name plate The type of gas specified MUST be used For proper conversion contact a qualified service technician or your Factory Authorized Service Center SHIPPING DAMAGE CLAIM PROCEDURE Merchandise must be inspected prior to the carrier leaving your premises Damage must be noted in writing on the BOL and pictures must be taken at this time For any goods shipped pre...

Page 4: ...ction is extremely dangerous LIGHTING Initial pilot lighting CAUTION When lighting pilots and checking for leaks do not Stand with your face close to the combustion chamber All Sierra appliances are adjusted and tested before leaving the factory effectively matching them to sea level conditions Adjustments and calibrations to assure proper operation may be necessary on installation to meet local c...

Page 5: ...movable appliances there is a restraining device at the rear of the unit If disconnection of the restraint is necessary reconnect the restraint after the appliance has been returned to its originally installed position CLEANING DAILY Clean top grate s with warm water mild cleaner and wire brush Clean and brush off debris from and around the burner area Empty and clean grease pan Griddle plates sho...

Page 6: ...r during the day and a stainless steel liquid cleaner at the end of the day To remove encrusted materials soak in hot water to loosen the material and then use a wood or nylon scraper Contact the factory factory representative or a local service company to perform repairs INSTALLATION OF LEGS LEGS ASSEMBLY Mount Legs on bottom of product the appliance may be further leveled with adjustment in the ...

Page 7: ...nstallation please read instructions completely and carefully Do not remove permanently affixed labels warnings or plates from the product Please observe all local and national codes and ordinances Installation must conform with local codes or in the absence of local codes the National Fuel Gas Code ANSI Z223 1 latest edition In Canada installation should conform to installation codes for gas burn...

Page 8: ... air conditioning system can produce a slight vacuum in the room and or cause air drafts either of which can interfere with the pilot or burner performance and could be difficult to diagnose Air movement should be checked during installation Air openings or baffles may have to be provided in the room if pilot or burner outage problem persists RATING PLATE Information on this plate includes the mod...

Page 9: ...LAME DRAFT CURRENTS NEAR EQUIPMENT FIX DRAFT NOT ENOUGH VENTILATION CONTACT HVAC CONTRACTOR DEBRIS OR GREASE CLOGGING PILOT BURNER CLEAN DEBRIS AND GREASE FROM PILOT BURNER EXCESSIVE FLARE UP OVERLOAD OF OIL AND LEFTOVERS CLEAN AND PREPARE PAN NOT HEATING PROPERLY ORIFICES DIRTY CLOGGED CLEAN ORIFICE MAKE SURE THERE IS NO RESTRICTION IN THE ORIFICE BURNER LOW GAS PRESSURE INCREASE GAS PRESSURE TO ...

Page 10: ...Sierra hereby states that warranty travel time shall be limited to and without exception a round trip total of two 2 hours OR mileage up to a maximum of one hundred fifty 150 kilometers round trip Any charges exceeding those stated herein must have prior authorization by the factory A special warranty covers the SRF series These units carry the regular one 1 year parts and labor plus an additional...

Page 11: ... 11 514 737 9701 888 275 4538 sales mvpgroupcorp com 5659 Royalmount Ave Montreal QC Canadá H4P 2P9 786 600 4687 844 218 8477 sales mvpgroupcorp com 12000 Biscayne Blvd Suite 108 Miami FL United States 33181 ...

Reviews: