High Volume/Output RTM Systems Operations Manual
Page | 23
Note
Refer to the Innovator II Control Panel component manual for additional
information.
13. The unit is ready to inject a part.
Shutting Down
1. If you need to end injection before the preset counter reaches zero, press the
Stop
button.
Note
The counter will stop the injection when the preset count is reached and close
the injection head.
2. Press the reset button on the counter to return the stroke count to zero.
3. Flush the injection head, feed hose(s), and any optional resin valves used.
4. Disconnect the resin feed hose from the injection head.
5. At this point if you need to inject another mold, return to the
Dispensing Material
steps.
6. If you need to shut down for the day, place the unit in recirculation mode, press the
Recirculation
button, and allow the unit to recirculate for about a minute.
7. Press the
Stop
button.
8. Turn off the main air slide valve on the back of the control box.
Troubleshooting
System Troubleshooting
Symptom
Possible Cause
Remedy
Will not start
injection or has
stopped during
injection sequence
No air supply
Make sure pressurized air line is connected to the
machine air inlet.
Stop button pushed
Press
Inject
button
Remote stop button pushed
Press
Inject
button
PPVS signal not being received
Install jumper between PPVS supply and PPVS signal if
no PPVS is being used
Check signal coming from PPVS if installed
Check internal PPVS circuits:
Check line (67) for leaks
Check V08 output (41) for signal (should be on)
MPG circuit is engaged
Check for blockage on resin delivery lines
Check FC 03 for proper adjustment
Check for air leaks on MPG valve and connection 1B-11
(26)
Check internal MPG circuits
Check (26) for leaks
Check (67) for leaks