Operation

1. The temperature controller (thermostat) is located on the upper left of the   back side of the 

p

(

)

pp

cabinet interior. 

2. The controller has been preset "NORMAL" position at the factory.

3. Set the control-knob toward "COOL" for higher temperature and "COLD"

for lower temperature.

4. The thermostat controls compressor's ON/OFF by sensing inside temperatures of cabinet.

5. The unit is equipped with an off-cycle defrost.

4

Visit us on the web at www.mvpgroupcorp.com

Summary of Contents for Kool-It KCD-36R

Page 1: ...KCD 36 48 CURVED CURVED GLASS GLASS DELY DELY C CASE ASE KCD 36R KCD 48R Visit us on the web at www mvpgroupcorp com ...

Page 2: ...of refrigeration system Indirect cooling Fan blowing Control Thermostat Control Shelve 1EA Glass Illumination 2EA LED Lamp Number of Doors 2 Sliding Door Rated Voltage AC115V 60Hz Type of Power Cord NEMA 5 15 Type of Power Cord NEMA 5 15 Amps 6 4A Compressor HP 3 8 HP Refrigerant R 134a Range of Temperature 35 44 F Specifications and Designs are subject to change without notice 2 Visit us on the w...

Page 3: ...al shock and fire hazards 2 Do not plug other electrical units into same wall receptacle this unit is plugged into 3 Do not use an extension cord 4 Compressor warranties are void if the compressor burns out due to low voltage Maintenance Cleaning Maintenance Cleaning 1 To maintain proper refrigeration performance the condenser fins should be checked monthly and clean with a soft brush or vacuum cl...

Page 4: ...e controller has been preset NORMAL position at the factory 3 Set the control knob toward COOL for higher temperature and COLD for lower temperature 4 The thermostat controls compressor s ON OFF by sensing inside temperatures of cabinet 5 The unit is equipped with an off cycle defrost 4 Visit us on the web at www mvpgroupcorp com ...

Page 5: ...ents from blocking the air duct Check the temperature controller for incorrect setting Check the refrigerant level it may need to be charged Check the door and be sure it is completely closed NO INTERIOR LIGHT Turn off the light switch and turn it on again Insert the bulb correctly into the socket Replace the bulb Install the unit on a leveled surface Maintain 7 inches of clearance from the wall U...

Page 6: ...ne 514 737 9701 Toll Free Telephone 888 275 4538 Fax 514 342 3854 Toll Free Fax 877 453 8832 Email sales mvpgroupcorp com Website www mvpgroupcorp com 6 Website www mvpgroupcorp com 12000 Biscayne Blvd Ste 108 Miami FL United States 33181 786 600 4687 844 218 8477 786 661 4100 ...

Reviews: