To toggle the DCHP setting to Yes, press the ENTER button.
To set a static address, DHCP should be set to No. Press the down
T
button to highlight the IP Addr:.
Press ENTER to change the address. A cursor will show on the first digit of the address. Use the up
S
and down
T
buttons to set each digit. Press the ENTER button to move to the next digit. Press BACK to
return to the previous digit. Upon completion, press the ENTER button to store the address in the
ENCOMPASS CM memory. Each segment of a valid IP address ranges from 0 to 255. Leading zeros are
necessary for segments lower than 100. Gateway and Netmask must also be set, following the same
method. If DHCP is set to Yes , these will be done automatically. Server and Port will be preset at the
factory. Should they be changed, contact NOC Control for current settings.
Push Model: DHCP must be set to No. Follow the instructions in the paragraph above to set the IP
address.
What to Expect
Upon applying power, the LCD on the face of the
ENCOMPASS CM1 will illuminate green and begin a startup routine.
Approximately 15 seconds later, the unit will begin playing audio and the LCD will display the artist name and song title.
If the unit is installed on a network, follow the steps under Network Settings, above, to set the IP address. At this point,
contact Muzak NOC by calling 800 327.6549. A network operator will collect installation details. If the unit is installed
on a network, the network operator will confirm remote that the unit is remotely addressable.
1
2
A
3
4
B
No user serviceable parts inside, breaking seal voids warranty
10/100 BASE-T
Tested to comply
with FCC standards
FOR HOME OR OFFICE USE
Environmental Operating Conditions & Physical Specifications
Use
Indoor
Audio
Unbalanced, 10K
Altitude
-975’ to 9,900’
Temperature Range
5
o
C to 45
o
C (drive constrained)
Relative Humidity
8 to 90% non-condensing
Weight (without power supply)
3.25 pounds
Dimensions (H x W x D)
4.25" x 6.8" x 8.25"
Power (Supply Voltage)
Input: 90-230 VAC, 50/60 Hz Output: 12 VDC @ 2
amps
Power Consumption
<25 watts
Device Approval
FCC Class A
Power Supply Approvals
FCC, UL, CSA, VDE
Last Updated: 13 October 2005, Version 5.00 / Based on Firmware 5.06