Note
- 3-Wire meat probes will work with a 2-Wire setting but a 2-
Wire meat probe WILL NOT work with a 3-Wire setting. If your 3-
Wire meat probe is not working, try setting it to 2-Wire.
Conductors are the number of
wires coming from the RTD.
2-Wire is almost always used for
chamber probes and most meat
probes.
3-Wire and 4-Wire are used for
high accuracy meat probes.
Click “Save” when done.
PT-1000
– By far the most
common meat probe –Default.
PT-100
– Is also common with
better accuracy and usually 3 or
4 wires.
The number after the metal type
is the resistance of the sensor at
0 C (32 F). For example:
PT-1000 = 1000 ohms @ 32 F
RTD TYPES
Resistance Temperature Detectors (RTDs) are used extensively in
pellet grills. PT-1000 and PT-100 probes are the most common.
Platinum (PT) and Nickel (NI) RTD types are settable under Model.
Temperature Probes in
Config Tab - Cont