Page 1: ...re for the media feed compensation value Refer to sheet 3 4 06b Chapter 5 Added the menu in 5 1 1 1 User Type advanced setup menu Refer to sheet 5 06b Added 5 1 1 1 8 Media thickness menu Refer to she...

Page 2: ...ickness from 80 m to 2800 m and then press the Enter key For the following procedure see the operation manual Confirmation pattern and Adjustment pattern are changed When the line is aligned the bold...

Page 3: ...Warming up Skip E is displayed on Operation panel This is not displayed for VJ 1624W since it does not perform warming up While Warming Up is displayed do not touch Platen and Media guide They become...

Page 4: ...Adjustment Change a Press the key or key and enter the micro adjustment value according to the printing result in Step 7 b Press the Enter key on Operation panel The micro adjustment value is saved Th...

Page 5: ...ickness menu Set the media thickness that you use Once the media thickness is entered print quality is automatically adjusted Setup item Setting Description Media Thickness 80 m to 170 m to 2800 m Ent...

Page 6: ...ed user type When you have selected ALL the setting values of the current user type are copied to the all other user types Enter key saves the setting and shifts to the previous menu Cancel key cancel...

Page 7: ...roll media remaining count is not used to judge for pausing printing Printing pauses when the rear sensor responds Enter key saves the setting and shifts to the sub menu Operation Manual 5 1 18 Exhau...

Page 8: ...xecuted in connection with computer the setting of RIP software will be printed in the Data Header Setup Item Set Value Description Header Dump Off Only a print data will be printed Damp data will not...

Page 9: ...1 Setup menu With take up system if you want to set Start Feed to below 0 set Page Gap to Narrow If not the Start Feed setting is not reflected properly 5 1 6 2 Page Gap menu 5 1 28 Heater Control Me...

Page 10: ...an select Off setting to avoid continuous buzzer beep Setup Item Setting Description Alert Buzzer On Press any key on Operation panel to turn off beep sound This is initially setting Off After several...

Page 11: ...luid valve and transfer the waste fluid to the container When transferring the waste fluid to the empty container the waste fluid may spatter Make sure to put the container close to the waste fluid va...

Page 12: ...ERRATA VJ 1624 1624W OPERATION MANUAL June 2018 VJ1624E A 06c 12 MUTOH INDUSTRIES LTD Setup menu diagram Ready to Print 1 4...