![Mutable Instruments Kinks Installation Download Page 2](http://html1.mh-extra.com/html/mutable-instruments/kinks/kinks_installation_1859974002.webp)
Rectifier and inverter
1.
Signal input.
2.
Inverted output.
3.
Half-wave rectified output.
The negative half of the signal
is clipped to 0V.
4.
Full-wave rectified output.
The negative half of the signal
is inverted.
Analog logic
1, 2.
Signal inputs.
3.
Analog OR (maximum,
peaks) output.
1
2
3
4
1
2
3
4
4.
Analog AND (minimum,
troughs) output.
Try this with envelopes or
LFOs, or to create new wave-
shapes from VCO outputs.
Sample&hold and
white noise
1.
Signal input, normalized to
the white noise generator.
2.
Trigger input. Requires a
signal with sharp rising edges
(clock/gate/trigger generator,
square LFO or VCO).
3.
Noise generator output.
4.
Sample and hold output.
1
2
3
4
MAX
Input signals
MIN