(1) Inspection
The following items are inside the box:
●
UPS unit ● User manual
(2) Connect to Utility Power
Connect AC power cord to utility power. Then, the UPS will start to charge inside
battery. For best result, charge the battery for 6 hours prior to initial use.
(3) Plug in Equipment
Battery Backup Outlets(3)
Connect computer and monitor to the "Battery Backup" outlets. These outlets provide
battery backup, EMI filtering, line conditioning, and surge protection. Battery power
is automatically provided in case of power failure.
Surge-Protected Outlets(3)
Connect a printer, fax machine, or scanner to the “Surge-protected” outlets. These
outlets do not provide power during power failure.
CAUTION: NEVER
connect a laser printer or scanner to the battery backup sockets
of UPS. The equipment may draw significantly power to overload the UPS.
(4) Turn On/Off the UPS
To turn on the UPS unit, press the power switch lightly. Then, the LED or LCD will light
up. To turn off the UPS unit, press the power switch again. Then, display will shut off.
LED
Alarm
UPS Status
●Green
Off
The mains is normal and UPS is
operated normally.
★
Yellow
Sounding every 10
seconds
Power failure occurs and UPS is on
battery mode.
★
Yellow Sounding every second
Low battery
○
Green
Off
UPS is off.
●Red
Continuously sounding
UPS fault
●LED on
○
LED Off
★
LED flashing
Problem
Possible Cause
Solutions
Nothing is
displayed on the
panel.
The UPS is not on.
Press the power switch again to turn
on the UPS.
Battery voltage is too
low.
Charge the battery at least
6 hours.
Battery fault.
Replace the battery.
The UPS always
on battery mode.
Power cord loose.
Re-plug the power cord.
Backup time too
short.
Battery voltage is too
low.
Charge the battery at least
6 hours.
Overload.
Remove some devices. Before
reconnecting equipment, please
check that the load matches the UPS
capacity specified in the specs.
Battery defect.
Replace the battery.
MODEL
PowerMust 600 LED
PowerMust 800 LED
CAPACITY
600VA/360W
800VA/480W
Input Voltage
220/230/240 VAC
Input Voltage Range
180-270 VAC
Output Voltage
Regulation
± 10 % (Bat. mode)
Transfer Time
Typical 2-6 ms
Waveform
Simulated Sine Wave
Battery Type
12V/4.5Ah
12V/5Ah
Battery Number
1
1
Charging Time
4-6 hours recover to 90% capacity
Dimension (DxWxH)mm
305 x 158.5 x 95
Net Weight (kgs)
2.6
2.9
Humidity
0-90% RH @ 0-40°C non-condensing)
Noise Level
Less than 40dB
Problem
Possible Cause
Solutions
Nothing is
displayed on
the panel.
The UPS is not on.
Press the power switch
again to turn on the UPS.
Battery voltage is too
low.
Charge the battery at least
6 hours.
Battery fault.
Replace the battery.
The UPS
always on
battery mode.
Power cord loose.
Re-plug the power cord.
The UPS
continuously
beeps.
Please check the fault
code for the details.
Please check the fault code
for the details.
Backup time
too short.
Battery voltage is too
low.
Charge the battery at least
6 hours.
Overload.
Remove some unnecessary
loads. Before reconnecting
equipment, please verify
that the load matches the
UPS capability specified in
the specs.
Battery defect.
Replace the battery.
4
5
Summary of Contents for PowerMust 600 LED
Page 28: ...Power on off 3 5mA 12VDC 6 1 2 3 4 5 Standby UPS 54 55...
Page 31: ...3 5mA 12VDC 6 1 2 3 4 5 Standby UPS 60 61...
Page 32: ...Mustek http www power software download com viewpower html 1 www Mustek eu FAQ USB UA 62 63...
Page 34: ...Power on off 3 5 12 6 1 2 3 4 5 Standby UPS 66 67...
Page 37: ...Power on off 3 5 12 6 1 2 3 4 5 Standby UPS Uputstvo za upotrebu 72 73...