background image

 

16 

 

The warranty is 1 year, and 5 years for the corpus of power suplly 

unit. 

ATTENTION! The official guarantee comes into force 

after registration on the websit

www.mustang-tat-

too.com/guarantee

You must register within 30 days 

from the date of purchase. 

 

Warranty exclusions

:

 

 problems after aggressive antiseptic agents 

 units with signs of falling, hitting, rust or processing 

 

 units with signs of self-modernization 

 

 misuse of equipment

  

connections of third-party adapters (not recom   mended for this unit). 

sterilization in an autoclave or dry oven

 

 

 

 

 

 

 

 

 

Summary of Contents for Expert Sensor

Page 1: ...USER S MANUAL ...

Page 2: ......

Page 3: ...roduction 2 Appointment 2 3 Equipment 2 3 Mount 2 3 Characteristics 4 Operations 5 Display 6 Beginning of work 7 Settings 8 11 Menu skin selection 12 13 Possible malfunctions 14 15 Warranty 16 Contacts 17 ...

Page 4: ...nc tionality despite its compact size This guide will allow you to fully appreciate the benefits and capabilities of the power supply Read the instructions carefully before starting work Purpose Complete set Mount Power supply for induction and rotary tattoo machines Stand power supply euro socket adapter instruction manual Magnetic mount for a secure fit Ideal for metal surfaces Anti slip and ant...

Page 5: ...Keyboard Tattoo machine connection ...

Page 6: ... in rubles dollars euros The function of auto detecting the type of machine 4 speeds of information output to the display Voltage 1 5 17 V And also additional features Ability to control the machine without a pedal Short circuit protection Sleeping mode Module for working with a wireless foot control MT Mustang Tattoo up to 128 connection options Sound key tone and display brightness settings Poss...

Page 7: ...es switching modes choosing the menu shell the number of machines currency brightness key tone language Pressing and holding will put the device into sleep mode Pressing simultaneously go to the settings menu Save settings and exit to the main screen Enables disables pedal sticking ...

Page 8: ... supply is equipped with a monochrome display with a blue indi cation The screen always displays the operating voltage and the previously selected memory cell The rest of the parameters depend on the screen shell ...

Page 9: ...The power supply turns on automatically when plugged in To access the settings menu simultaneously press and hold the left and right keys To select a specific menu item To save the settings and exit ...

Page 10: ... left and right keys Press left or right to enable or disable auto detection Adjustable with the left or right buttons Time clock Time minutes Number of machines Select the item and set the clock using the LEFT and RIGHT keys Select an item and adjust the minutes using the left and right keys 2 4 6 ...

Page 11: ...peed Key sound To disable enable the mode press the left and right keys Switch between speeds buttons left right There are 4 speeds of information output slow medium fast and maximum Press the left or right key to adjust ...

Page 12: ...The function allows you to calculate the hourly cost of the session Decrease increase rate buttons left or right Units Press left or right to select currency Version Working hours Software version The total running time of the power supply unit since the pur chase ...

Page 13: ... right to select the navigation language Exit Press to exit to the main screen Pedal Sticky In Home screen mode press and hold the key to turn sticky on or off When the mode is on an m icon is dis played on the screen SETTINGS ...

Page 14: ...ltage time and memory cell are on the left side of the screen on the right frequency load operat ing mode of the machine current value 2 The working voltage is displayed in large size in small print the price the duration of the session the operat ing time of the machine the clock the memory cell ...

Page 15: ...13 3 The clock is large in the upper part under it is the volt age the duration of the session the operating time of the machine the memory cell 4 The screen displays only operating voltage memory cell ...

Page 16: ...ers while output power ripple Contact MT Mustang Tattoo Authorized Service Center The power adapter is most likely defective Problem 3 Solution Power is on but no signal is being sent to the tattoo machine Click on the button See if there is a change in the display It is possible that the wire or tattoo machine is faulty Try using a different wire or tattoo machine ...

Page 17: ...e on the display Does the display change when you press the pedal It is possi ble that the wire or tattoo machine is faulty Try using a different wire or tattoo machine The machibe continues to operate when the pedal is depressed although the pedal stick mode is enabled on the power supply unit Disable the Sticky mode according to the in structions ...

Page 18: ...g tat too com guarantee You must register within 30 days from the date of purchase Warranty exclusions problems after aggressive antiseptic agents units with signs of falling hitting rust or processing units with signs of self modernization misuse of equipment connections of third party adapters not recom mended for this unit sterilization in an autoclave or dry oven ...

Page 19: ...ipment and its parts as a result of proper or improper use Within three months after purchase the product can be ex changed for a similar model Return is allowed within two weeks Service Center Contacts Russia Moscow Narodnaya str 14 1 tel 7 499 754 85 25 www mustang tattoo com ...

Page 20: ......