11
6.
Secure the webbed pull handle on the Velcro™ patch (Figure
13) and guide the webbed handle through the hole in the fabric
inflation cover (Figure 14).
FIGURE 14
7.
Replace the fabric inflation cover and secure with Velcro™
closure.
8.
Repeat steps 1 to 7 for right cell.
REPACKING THE PFD
AFTER EACH FIELD-USE INFLATION, THE MD1270 MUST BE RE-ARMED, LEAK TESTED,
AND FULLY DEFLATED BEFORE REPACKING.
GAS REMOVAL FROM THE INFLATION CELLS
WARNING:
FOR THE SMALLEST PACKED VOLUME, ALL GAS MUST BE EVACUATED
FROM THE LEFT AND RIGHT BLADDERS PRIOR TO PACKING THE PFD.
1.
You will need a vacuum source capable of achieving at least
5 in-Hg and a vacuum fitting to connect it to the oral inflator
(a 3 HP shop vacuum will provide more than 5 in-Hg of vacuum).
A 3 HP SHOP VACUUM WILL PROVIDE MORE THAN 5 IN-HG OF VACUUM.
2.
Place each bladder on a flat surface with the inflator and oral
tube facing up.
FIGURE 15