Inflatable PFD Re-Arm Kit

  MA7218

WARNING

·  Use only with specified PFD models.
·  This gas cylinder is under pressure, therefore misuse can 

be dangerous.

·  Do not incinerate, expose to sunlight or store above 120˚F 

(50˚C).

·  Do not throw into open fire or dump at sea.
·  Keep away from children.
·  Dispose of gas cylinders only when empty.
·  Discharge and dispose of corroded or rusty cylinders.

IMPORTANT

: Please review and follow additional 

maintenance instructions in your Owner’s Manual.

Re-arming instructions

1.  Place the Inflatable PFD (Personal Flotation Device) on a 

smooth, flat surface and wipe off any water. Access the 
inflator by reaching under the cover and pull it toward 
you, turning the cell and cover inside out to fully expose 
the inflator for re-arming. Hold the CO2 cylinder through 

the fabric, using one hand (Fig. 1).

2.  Insert the metal key between the black locking ring and 

labeled yellow cap. Turn the key counter-clockwise (Fig. 2).

3.  Turn the black locking ring counter-clockwise and lift off 

the cap (yellow inflator operating head Fig. 3). Dispose of 
the used cap

.

4.  Squeeze the sealing ring to elongate and remove the 

inflator body through the sealing ring (Fig. 4).

5.  Dispose of the used inflator body (Fig. 5).

6.  Check that the new inflator body indicator is green. Insert 

the new inflator body with CO2 cylinder pointing upward 

inside the Inflatable PFD. Let the sealing ring rest on the 
adapter around the four lugs (Fig. 6).

7.  Now check the new manual/automatic cap as follows (Fig. 7): 

1. Is the single point status indicator showing green? 
2. Is the expiry date OK? 
If YES is the answer to both questions, then proceed as 
follows. If the answer is NO to either question, get a new cap.

Figure 1

8.  Hold the CO2 cylinder through the fabric of the Inflatable 

PFD (Fig 8a). Position the replacement cap with the water 
inlet valve pointing to the right and press firmly onto the 
inflator body and sealing ring (Fig. 8b).

9.  While pressing FIRMLY onto the inflator body, turn the 

BLACK locking ring clockwise into the locked position (Fig. 
9). Pull on the cap to make sure it has locked onto the 
inflator body.

 

10. Check: To see that the single point status indicator on the 

cap is green; the pull to inflate lanyard is present and that 
the locking ring is locked.

 11. If your Inflatable PFD has been used and/or the inflator 

replaced, always inflate through the oral tube and 
check that it stays inflated at least overnight. Empty the 
Inflatable PFD again by reversing the oral-inflation tube 
dust cap and inserting it into the valve or by depressing 
the valve with fingertip. Gently squeeze the inflatable PFD 
until all air or gas has been expelled. Let the Inflatable 
PFD dry before packing. 

IMPORTANT: Ensure all air is removed before repacking.

 12. Refold the Inflatable PFD in accordance with the 

Repacking section of the owner’s manual.

Figure 2

LOCKING RING KEY

Figure 3

CAP

Figure 4

INFLATOR BODY

SEALING RING

RED  
INDICATOR

Figure 6

GREEN 
INDICATOR

CAUTION: 
DO NOT TURN 
THE CENTER 
SHAFT

Figure 7

SINGLE 
POINT INDICATOR

WATER 
INLET VALVE

Figure 9

BLACK 
LOCKING RING

Figure 8b

90º

Figure 8a

Figure 5

RED INDICATOR

TRASH

Re-arm kit for 

Mustang survival

 Models:

Trousse de réarmement pour les modèles de V.F.I.  
de 

Mustang survival

:

MD0450 & MD0451

Inflatable PFD

Re-arm Kit

VFI gonflable  

Ensemble de réarment

Reviews: