SPECIFICATIONS
ELECTRICAL CONNECTION
A 15 Amp, 120 Volt, 60 Hz circuit with a properly grounded outlet is required to operate this appliance.
Preferably, the stove will be on a dedicated circuit as other appliances on the same circuit may cause the
circuit breaker to trip or the fuse to blow when the heater is in operation. The unit comes standard with a
4.5 ft (1.5 m) long 3 wire cord, exiting out the back of the stove. Plan the installation to avoid the use of
an extension cord. If an extension cord must be used, it must be a minimum 14 ga, 3 wire with
grounding type plug and connector and rated not less than 2025 watts. The extension cord shall not be
more than 20 ft (6 m) in length.
WARNING:
Electrical outlet wiring must comply with local building codes and other
applicable regulations to reduce the risk of fire, electrical shock and injury to persons.
WARNING:
Do not use this stove if any part of it has been under water. Immediately call a
qualified service technician to inspect the stove and replace any part of the electrical system
which has been under water.
SERVICE INSTRUCTIONS
FOR YOUR SAFETY
Service must be performed by a qualified service agency.
REPLACING THE LIGHT BULBS
NOTE: Light bulbs may become loose during shipment. If the flame effect is dim or does not work, please
check that the light bulbs are lightly secured into their sockets. See instructions for replacing the bulbs.
The MES31CR, MES31MB and the MES31BL use two (2) clear 120 Volt, 25 watt B-10,
E-12 socket base light bulbs (small base, chandelier candle type bulbs). The access plate is located on
the back of the unit. For convenience, if one of the light bulbs burns out, it
may be easier to replace both of the light bulbs at the same time.
CAUTION:
To reduce the risk of fire, use 25 watt ONLY,
TYPE B-10, E-12 socket base light bulbs.
Dimensions W x D x H
20.5” x 13.5” x 25”
53 cm x 35 cm x 64 cm
Net Weight
Gross Weight
38 lbs / 17 kg
47 lbs / 21 kg
Voltage
120 V
Frequency
60 Hz
Watts
1400 W
Heater Rating