musikelectronic geithain TS56KSP Instructions For Installation And Use Manual Download Page 5

 SYSTEM DESCRIPTION

3

musikelectronic geithain GmbH

TS 56SP  /  TS 56KSP

System description

The active, coaxial two-way sound reinforcement systems TS 56KSP and TS 56SP feature a neutral 
sound  colour,  strong  vertical  directivity  and  high  dynamics.  The  active  concept  allows  flexible 
adjustments to acoustical conditions and guarantees a perfect combination of speakers and amplifiers. 
Thanks to pre-programmed presets a combination of our active subwoofers and speakers saves the 
time to configure a loudspeaker management system and immediately offers a perfectly adjusted 
system. Compared to the provided power the speakers are very compact. These active systems are 
engineered for high class speech and music reproduction in middle sized auditoria. In addition they 
remain  optically  discrete  because  of  their  small  dimensions.  The  abandonment  of  horn  speakers 
results in a neutrality you only know from first class studio monitors.

The  components  include  one  10-inch  cone  woofer  and  eight  1-inch  dome  tweeters.  Both  are 
effectively  secured  from  destruction  by  an  internal  limiter.  The  coaxial  arrangement  ensures  a 
homogeneous  dispersion  and  this  also  reduces  the  size  of  these  powerful  sound  reinforcement 
systems. The speakers are available in the proven vented cabinet or with cardioid technology. The 
port  tuning  of  the  TS 56SP  reaches  a  lower  cut-off  frequency  of  65 Hz.  The  resulting  bass  level 
enables the use as a full-range system in many situations. Optionally our TT-subwoofers can be 
employed to extend the bass transmission range by more than one octave. Because of the strong 
vertical directivity, distractions by ceiling and floor reflections are effectively reduced. Thanks to this 
technical  feature  the  operation  of  these  speaker  systems  in  acoustically  difficult  environments  is 
simplified. The TS 56KSP executed in cardioid technology additionally supports the user on handling 
this task in low frequency range.

A variety of available mountings provide easy assembly for almost every application.

Summary of Contents for TS56KSP

Page 1: ...musikelectronic geithain TS 56SP TS 56KSP Instructions for installation and use...

Page 2: ...elivery contents 14 5 5 Cleaning 14 5 6 Environmental conditions 14 5 7 Guarantee acknowledgements 14 6 Controls and connections 15 7 Installation and operation 17 7 1 Mounting and positioning 17 7 2...

Page 3: ...kers You decided upon a quality product that in regard to tonal and technical characteristics complies to the utmost expectations The usual burn in period is not required because the speakers are arti...

Page 4: ...sold through authorized fulfillers and resellers only Fulfillers and resellers are not agents of Musikelectronic Geithain GmbH and have absolutely no authority to bind Musikelectronic Geithain GmbH by...

Page 5: ...rst class studio monitors The components include one 10 inch cone woofer and eight 1 inch dome tweeters Both are effectively secured from destruction by an internal limiter The coaxial arrangement ens...

Page 6: ...SPL r 1m 3 3 Mains voltage 85V 260V Power consumption Maximum No load Stand by 800W 25W 16W Mains connectors 1 Powercon 1 Powercon loop through output Amplifier type 2 channel PWM amplifier with tempe...

Page 7: ...g temperature Storage temperature Relative humidity 15 C 35 C 59 F 95 F 25 C 45 C 13 F 113 F 45 75 Design of the cabinet lumber core plywood with scratch proof structure coating black RAL9005 other co...

Page 8: ...6KSP 4 2 Acoustical diagramms 25 50 100 200 500 1k 2k 5k 10k 20k 100 95 90 85 80 75 dB Hz 0 TS56SP 0 TS56KSP 45 h 180 h TS56KSP Preset speech 20 50 100 200 500 1k 2k 5k 10k 20k dB Hz 20 15 10 5 0 TS56...

Page 9: ...SPECIFICATIONS 7 musikelectronic geithain GmbH TS56SP TS56KSP 4 3 Technical drawings 4 3 1 TS56SP...

Page 10: ...SPECIFICATIONS 8 musikelectronic geithain GmbH TS56SP TS56KSP 4 3 2 TS56KSP...

Page 11: ...onmental regulations Ensure disposal of damaged mounting accessories before they could be reused But do not dispose these products and accessories at official collecting points for recycling either Di...

Page 12: ...in except Germany mentioned in the WEE from 08 13 2005 onwards with a sign with a crossed out waste bin and a white bar below This sign indicates that the disposal into the domestic waste is prohibite...

Page 13: ...oduct may fall causing serious injury and damage to the product The heat sink must not be blocked or covered This product should not be installed unless proper ventilation is provided or manufacturer...

Page 14: ...ll service and repair work must be carried out by an authorised retailer or an authorised repair and maintenance shop or the manufacturer When replacement parts are required please ensure that only re...

Page 15: ...nings as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock Never spill liquid of any kind on the device Connecting When you connect the device to...

Page 16: ...evice please refer to the additional user manual for unboxing 5 4 Delivery contents Speaker TS56SP or TS56KSP Powercon cable Technical description and user manual 5 5 Cleaning The speaker is made of r...

Page 17: ...CONTROLS AND CONNECTIONS 15 musikelectronic geithain GmbH TS56SP TS56KSP 6 Controls and connections 1 2 3 4 5 6 7 8 9 10 11...

Page 18: ...or clipping BACK button 5 Controls the device and is used to navigate the menu and to set parameters see chapter 8 Operation and configuration of the device page 20 USB port type B 6 Used to configur...

Page 19: ...ronment or persons Therefore stacked speakers are to be secured with safety straps Connecting cables have to be installed so that nobody trips Stability of stacked systems including stands and distanc...

Page 20: ...isual inspection of all outside parts for obvious damage e g scratches damages of any kind visual inspection of all mounting accessories for obvious damage e g scratches corrosion inspection of front...

Page 21: ...erm installations a permanent connection to the network is advisable to ease the maintenance respective configuration capabilities of the speakers Ensure all cables are installed in a way that nobody...

Page 22: ...neath is the Preset menu used to load and save presets show the serial number of the DSP module and switch to the LOCKED status The signal processing parameters of the currently loaded preset are conf...

Page 23: ...ritten so that it is always possible to restore the factory settings Handling the menu item SAVE works in the same way After choosing a save location insert a name for the preset Chapter 8 6 Entering...

Page 24: ...b item shown in the first similarly to selecting an input If no arrow is shown between input and sub item the parameter is changeable through the rotary encoder Pressing down the rotary encoder browse...

Page 25: ...rent slopes filter characteristics and variable frequencies Freq 50Hz 20 000Hz Type BUT 6 12 18 24dB BES 6 12 18 24dB LR 12 24dB Enabled Off On HighPass Use high pass filtering on the input signal wit...

Page 26: ...nd digital input signals so that the settings of the left channel are automatically copied to the right channel Off On 8 6 Entering names and passwords To insert strings like names and passwords throu...

Page 27: ...rd protected The LOCKED level prevents changes to the configuration of the device by unauthorized personnel The device could be started up in the LOCKED mode or USER mode Firmware actualization Equali...

Page 28: ...No sound Speakers are not connected correctly Examine the XLR connections to the speakers In outputs are muted Deactivate muting at the de vice or in the software No input signal available Apply an a...

Page 29: ...NOTES 27 musikelectronic geithain GmbH TS56SP TS56KSP 11 Notes...

Page 30: ...NOTES 28 musikelectronic geithain GmbH TS56SP TS56KSP...

Page 31: ...NOTES 29 musikelectronic geithain GmbH TS56SP TS56KSP...

Page 32: ...DIO MONITORING HIGHEND LOUDSPEAKER SOUND REINFORCEMENT SYSTEMS SYSTEMS Nikolaistra e 7 04643 Geithain Germany Phone 49 0 34341 3110 Fax 49 0 34341 31144 Email info me geithain de www me geithain de BD...

Reviews: