background image

 

Issue 2                                             

 

 

Page 10 of

 

11 

SPECIFICATIONS

 

Output 

Power 

260 Watts per channel into 8 Ohms (24 dBW) 

Voltage 

46 Volts RMS, 20Hz to 20 kHz; onset of clipping 

 

(130 Volts peak-to-peak) 

 

Current peak-to-peak 

140 Amps 

Damping factor 

210 

Output devices  

4 pairs per channel 

 

Line input 

THD+N 

<0.007% typical, 20 Hz to 20 kHz 

Signal / noise ratio 

>120 dB ‘A’-weighted 

Input impedance 

50k Ohms 

Frequency response 

+0, –1dB, 10Hz to 100 kHz 

 

Connections 

Line level inputs 

1 pair line level XLR (balanced) connectors 

 

2 pairs line level RCA connectors 

Line level outputs 

1 pair line level RCA connectors 

 

Speaker outputs 

4 pairs 4mm banana plug/binding posts 

 

Power requirement 

Mains voltages 

115/230VAC 50/60Hz (factory pre-set) 

 

100VAC 50/60Hz (alternative) 

Consumption 

750 Watts maximum 

 

Weight 

Unit only, unboxed  

19.7 kg (43

 lbs) 

 

 

In shipping carton  

24.4 kg (53

 lbs) 

 

 

Dimensions 

Wide  

440 mm (17

 ”) 

 

High, including feet  

125 mm (5 ”)   

Deep (front to back) including terminals   390 mm (15

 ”) 

 

 

Standard accessories 

IEC type mains lead (10-Amp type) 
 
 

 

Musical Fidelity reserves the right to make improvements which may result in 

specification or feature changes without notice. 

 

 

Summary of Contents for M6PRX CRPS

Page 1: ...fied choke regulated power supplies also ensure the absolute best in supply noise filtering separation and power reserve possible in a single box power amplifier This combination yields one of the best high fidelity systems available at any price Used properly and carefully it should give many years of outstanding musical reproduction Dust regularly with a soft duster or soft brush but be careful ...

Page 2: ...tions 4 Disposal information EU disposal information 5 Installation Introduction cleaning installation power connections audio connections 6 Facilities and connections Illustrations main unit front rear panels 7 Operation Starting Input A RCA Input B RCA Input B balanced 8 Problems Basic fault finding 9 Specifications 10 Manual history 11 ...

Page 3: ...ce may not correspond with the coloured markings identifying the terminals in the plug proceed as follows The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or coloured green or green and yellow or by the earth symbol The wire which is coloured brown must be connected to the terminal which is marked with the letter L or colou...

Page 4: ...et and inform your dealer who should then check the unit before further use Entry of liquid into the M6PRX is dangerous and may cause electric shock or fire hazard Do not place the unit near direct heat sources such as radiators direct sunlight or other equipment Do not remove any covers or try to gain access to the inside There are no internal adjustments or fuses you can replace yourself Refer a...

Page 5: ...ACHGERECHTE ENTSORGUNG Das auf der Geräterückseite angebrachte Label deutet darauf hin dass das Produkt nicht mit konventionellem Hauskehricht entsorgt werden darf Um Schäden und Verschmutzungen an Umwelt und Mensch zu vermeiden muss das Produkt fachgerecht entsorgt und von anderem Abfall getrennt werden Wenden Sie sich bei Fragen hierzu an Ihren Fachhändler oder an eine öffentliche Informationsst...

Page 6: ...ty of power at all times and it is important that it is adequately ventilated The top and bottom are perforated to allow the smooth flow of heat through the unit It is therefore not recommended that the unit is enclosed in a cabinet or placed where the ventilation holes are impeded as this could result in excessive heat build up The M6PRX must be protected from humidity if the unit is moved from a...

Page 7: ...A B indicator LEDs 5 INPUT selector button 6 7 8 9 10 11 12 13 14 6 LOUDSPEAKER OUTPUTS Right 7 BALANCED XLR right input 8 BALANCED RCA Selector for INPUT B 9 BALANCED XLR left input 10 LOUDSPEAKER OUTPUTS Left 11 IEC MAINS INPUT 12 LOOP output RCA sockets 13 INPUT B RCA sockets 14 INPUT A RCA sockets ...

Page 8: ...PUT select button so INPUT A LED is lit INPUT B RCA To use the RCA INPUT B connect RCA source outputs to the INPUT B RCA sockets see page 7 Make sure the BALANCED RCA switch is set for RCA down Select INPUT B by pressing the INPUT select button so INPUT B LED is lit INPUT B BALANCED To use the balanced input connect balanced source outputs to the balanced input XLR sockets see page 7 Make sure the...

Page 9: ...when bi wiring or bi amping that speaker bass and treble linking straps are removed see speaker manual for more information Sound is not precise lacking in bass and stereo image Speakers are connected out of phase i e connections to one speaker and are reversed Ensure speakers are connected with same polarity at amplifier and speaker ends Hum Audio connector plug not fully pushed in Cable Fault Un...

Page 10: ...vel XLR balanced connectors 2 pairs line level RCA connectors Line level outputs 1 pair line level RCA connectors Speaker outputs 4 pairs 4mm banana plug binding posts Power requirement Mains voltages 115 230VAC 50 60Hz factory pre set 100VAC 50 60Hz alternative Consumption 750 Watts maximum Weight Unit only unboxed 19 7 kg 43 lbs In shipping carton 24 4 kg 53 lbs Dimensions Wide 440 mm 17 High in...

Page 11: ...Issue 2 Page 11 of 11 MANUAL HISTORY RELEASE DATE CHANGES Issue 1 14th October 2009 1st Issue Issue 2 9th November 2009 Back panel updated ...