Music & Lights ProLights ARCLED7136 User Manual Download Page 20

ARCLED7136

2

WARNING! Before carrying out any operations with the unit, carefully read this instruction 

manual and keep it with cure for future reference. It contains important information about the 

installation, usage and maintenance of the unit.

SAFETY

General instructions

• 

The products referred to in this manual conform to the European Community Directives and are therefore marked with  .

• 

The unit is supplied with hazardous network voltage (230V~). Leave servicing to skilled personnel only. Never make 
any modifications on the unit not described in this instruction manual, otherwise you will risk an electric shock.

• 

Connection must be made to a power supply system fitted with efficient earthing (Class I appliance according to 
standard EN 60598-1). It is, moreover, recommended to protect the supply lines of the units from indirect contact and/
or shorting to earth by using appropriately sized residual current devices.

• 

The connection to the main network of electric distribution must be carried out by a qualified electrical installer. Check that 
the main frequency and voltage correspond to those for which the unit is designed as given on the electrical data label. 

• 

This unit is not for home use, only professional applications.

• 

Never use the fixture under the following conditions:

- in places subject to vibrations or bumps;
- in places with a temperature of over 45°C or less than 2°C.

• 

Make certain that no inflammable liquids, water or metal objects enter the fixture.

• 

Do not dismantle or modify the fixture.

• 

All work must always be carried out by qualified technical personnel. Contact the nearest sales point for an inspection 
or contact the manufacturer directly.

• 

If the unit is to be put out of operation definitively, take it to a local recycling 
plant for a disposal which is not harmful to the environment.

Warnings and installation precautions

• 

Never look directly at the light beam. Please note that fast changes in lighting, e. g. flashing light, may trigger epileptic 
seizures in photosensitive persons or persons with epilepsy. 

• 

Before starting any maintenance work or cleaning the projector, cut off power from the main supply. 

• 

Make certain that the fixture is off and the temperature of the components cannot cause burns. 

• 

Always additionally secure the projector with the safety rope. When carrying out any work, always comply scrupu-
lously with all the regulations (particularly regarding safety) currently in force in the country in which the fixture’s 
being used. 

• 

Keep any inflammable material at a safe distance from the fixture.

• 

Shields, lenses or ultraviolet screens shall be changed if they have become damaged to such an extent that their ef-
fectiveness is impaired.

• 

The lamp (LED) shall be changed if it has become damaged or thermally deformed.

• 

Don’t connect the device to a dimmer pack.

GENERAL INFORMATION

Shipments and claims

The goods are sold “ex works” and always travel at the risk and danger of the distributor. Eventual damage will have to be 
claimed to the freight forwarder. Any claim for broken packs will have to be forwarded within 8 days from the reception 
of the goods.

Warranty and returns

The guarantee covers the fixture in compliance with existing regulations. You can find the full version of the “General 
Guarantee Conditions” on our web site www.musiclights.it. Please remember to register the piece of equipment soon 
after you purchase it, logging on www.musiclights.it. The product can be also registered filling in and sending the form 
available on your guarantee certificate. For all purposes, the validity of the guarantee is endorsed solely on presentation 
of the guarantee certificate. Music & Lights will verify the validity of the claim through examination of the defect in rela-
tion to proper use and the actual validity of the guarantee. Music & Lights will eventually provide replacement or repair of 
the products declining, however, any obligation of compensation for direct or indirect damage resulting from faultiness.

The information provided in this manual has been carefully checked.

However Music & Lights S.r.l. is not responsible for any possible inaccuracy.

Summary of Contents for ProLights ARCLED7136

Page 1: ...I GB Manuale Utente User Manual ARCLED7136 ARCHITAINMENT LED PROJECTOR...

Page 2: ...REV 002 04 10...

Page 3: ...installazione Informazioni generali 1 Descrizione e specifiche tecniche 1 1 Elementi di comando e collegamenti 1 2 Descrizione 1 3 Specifiche tecniche 2 Installazione 2 1 Montaggio 3 Funzioni e impos...

Page 4: ...rete di alimentazione Assicurarsi che l unit sia spenta e che la temperatura delle parti non possa provocare ustioni assolutamente necessario proteggere l unit per mezzo di una fune di sicurezza Nell...

Page 5: ...XLR a 3 poli 1 massa 2 DMX 3 DMX 4 DMX IN XLR a 3 poli 1 massa 2 DMX 3 DMX 5 POWER IN per il collegamento ad una presa di rete 100 240V 50 60Hz tramite il cavo rete in dotazione 6 POWER OUT output ali...

Page 6: ...a definizione Angolo di proiezione 15 25 45 60 disponibili su richiesta Durata media diodi LED 75 000 ore Funzionamento ed elettronica Diverse configurazioni DMX disponibili 3 4 5 9 canali per control...

Page 7: ...i collocazione deve avere una stabilit sufficiente e supportare almeno 10 volte il peso dell unit Fissare il proiettore attraverso l apposita staffa 1 ad una collocazione idonea assolutamente necessar...

Page 8: ...ore ARCLED7136 dispone di un LED display e 4 pulsanti per accesso alle funzioni del pannello di controllo fig 3 Nota Dopo circa 6 secondi fra due pressioni dei tasti la procedura d impostazione entra...

Page 9: ...WN D512 D001 UP DOWN IDON IDOF ENTER UP DOWN ID00 ID50 AUTO ENTER UP AT8F AT1F DOWN AT1F AT1O ENTER SP01 T008 UP DOWN UP DOWN T008 T255 SP01 SP25 TESR TESb T000 ENTER UP DOWN X255 X000 TEST ENTER UP D...

Page 10: ...siderato Auto o personalizzato e premere il tasto ENTER per confermare Servirsi dei connettori DMX presenti sul pannello di controllo dell ARCLED7136 e di un cavo XLR per formare una catena di unit In...

Page 11: ...a un semplice layout DMX con tre unit ciascuna con un valore DMX Le tre unit han no diversi indirizzi ID che consentono all utente di controllare l intero gruppo con il medesimo valore DMX ponendo CH9...

Page 12: ...di connessione riportato di seguito 1 3 2 1 2 3 DMX OUTPUT Presa XLR DMX INPUT Spina XLR Pin1 Massa Schermo Pin2 Negativo Pin3 Positivo ATTENZIONE La parte schermata del cavo calza non deve mai essere...

Page 13: ...ta la fine della linea stessa venga riflesso indietro lungo il cavo provocando in certe condizioni e lunghezze la sua sovrapposizione al segnale originale e la sua cancellazione La terminazione deve e...

Page 14: ...R 000 255 2 RED 0 100 000 255 3 GREEN 0 100 000 255 4 BLUE 0 100 000 255 5 STROBO 0 100 000 255 Channel Function in STAG mode DMX value 1 DIMMER 0 100 000 255 2 RED 0 100 000 255 3 GREEN 0 100 000 255...

Page 15: ...Function in ARCD mode DMX value 1 MASTER DIMMER 000 255 2 RED 0 100 000 255 3 GREEN 0 100 000 255 4 BLUE 0 100 000 255 Channel Function in ARC mode DMX value 1 RED 0 100 000 255 2 GREEN 0 100 000 255...

Page 16: ...tal mente esenti da qualsiasi deformazione I cavi di alimentazione devono essere in condizione impeccabile e devono essere sostituiti immediata mente nel momento in cui anche un piccolo problema viene...

Page 17: ......

Page 18: ......

Page 19: ...n precautions General information 1 Description and technical specifications 1 1 Operating elements and connections 1 2 Description 1 3 Technical specifications 2 Installation 2 1 Mounting 3 Functions...

Page 20: ...t may trigger epileptic seizures in photosensitive persons or persons with epilepsy Before starting any maintenance work or cleaning the projector cut off power from the main supply Make certain that...

Page 21: ...S 1 1 Operating elements and connections Fig 1 1 Mounting bracket 2 Locking knob for the mounting bracket 3 DMX OUT 3 pole XLR 1 ground 2 DMX 3 DMX 4 DMX IN 3 pole XLR 1 ground 2 DMX 3 DMX 5 POWER IN...

Page 22: ...r range High efficiency precise optics Projection angle 15 25 45 60 available on demand LEDs average life span 75 000 hours Electronics and features Several DMX configurations selectable 3 4 5 and 9 c...

Page 23: ...support a weight of 10 times of the unit s weight Install the projector at a suitable location by means of the mounting bracket 1 Always additionally secure the projector with the safety rope from fal...

Page 24: ...itch 3 2 Basic Access control panel functions using the four panel buttons located directly underneath the LED Display fig 3 NOTE Never wait for more than 6 seconds to press the next button otherwise...

Page 25: ...D512 D001 UP DOWN IDON IDOF ENTER UP DOWN ID00 ID50 AUTO ENTER UP AT8F AT1F DOWN AT1F AT1O ENTER SP01 T008 UP DOWN UP DOWN T008 T255 SP01 SP25 TESR TESb T000 ENTER UP DOWN X255 X000 TEST ENTER UP DOW...

Page 26: ...he desired program Auto or Custom and press the button ENTER to confirm Use standard DMX cables to daisy chain your units together via the DMX connector on the rear of the units For longer cable runs...

Page 27: ...the user to collectively control the whole group of units at that DMX address by setting CH9 0 or to control each unit independently by first selecting the DMX ad dress and the by using CH9 to locate...

Page 28: ...ATTENTION The screened parts of the cable sleeve must never be connected to the system s earth as this would cause faulty fixture and controller operation Over long runs can be necessary to insert a...

Page 29: ...DMX 512 signals being reflected back along the cable when they reaches the end of the line under certain conditions and with certain cable lengths this could cause them to cancel the original signals...

Page 30: ...00 255 2 RED 0 100 000 255 3 GREEN 0 100 000 255 4 BLUE 0 100 000 255 5 STROBO 0 100 000 255 Channel Function in STAG mode DMX value 1 DIMMER 0 100 000 255 2 RED 0 100 000 255 3 GREEN 0 100 000 255 4...

Page 31: ...Function in ARCD mode DMX value 1 MASTER DIMMER 000 255 2 RED 0 100 000 255 3 GREEN 0 100 000 255 4 BLUE 0 100 000 255 Channel Function in ARC mode DMX value 1 RED 0 100 000 255 2 GREEN 0 100 000 255...

Page 32: ...condition and should be replaced immediately even when a small problem is detected The interior of the device should be cleaned annually using a vacuum cleaner or air jet It is recommended to clean t...

Page 33: ......

Page 34: ......

Page 35: ...conseguenti sono a carico del possessore dell apparecchio A tutti gli effetti la validit della garanzia avallata unicamente dalla presentazione del certificato di garanzia The guarantee covers the un...

Page 36: ...ate Data acquisto FORM TO BE FILLED IN AND MAILED CEDOLA DA COMPILARE E SPEDIRE FORM TO BE FILLED IN AND KEPT CEDOLA DA COMPILARE E CONSERVARE PROV ZIP CODE C A P MODEL MODELLO SERIAL N SERIE N Purcha...

Page 37: ......

Page 38: ......

Page 39: ......

Page 40: ...usic Lights S r l PROLIGHTS is a brand of Music Lights S r l company Via Appia Km 136 200 04020 Itri LT ITALY tel 39 0771 72190 fax 39 0771 721955 www musiclights it info musiclights it Music Lights S...

Reviews: