Before carrying out any operations with the unit,  
carefully read this instruction manual, and keep it 
with cure for future reference.
It  contains  important  information  about  the 
installation, usage and maintenance of the unit.

SAFETY

General instruction

• 

The products referred to in this manual con-

form to the European Community Directives 

and are therefore marked with  .

• 

The unit is supplied with hazardous network 

voltage  (230V~).  Leave  servicing  to  skilled 

personnel  only.  Never  make  any  modifica-

tions  on  the  unit  not  described  in  this  in-

struction manual, otherwise you will risk an 

electric shock.

• 

Connection must be made to a power supply 

system  fitted  with  efficient  earthing  (Class  I 

appliance  according  to  standard  EN  60598-

1). It is, moreover, recommended to protect 

the  supply  lines  of  the  units  from  indirect 

contact and/or shorting to earth by using ap-

propriately sized residual current devices.

• 

The connection to the main network of elec-

tric  distribution  must  be  carried  out  by  a 

qualified  electrical  installer.  Check  that  the 

main  frequency  and  voltage  correspond  to 

those for which the unit is designed as given 

on the electrical data label. 

• 

This  unit  is  not  for  home  use,  only  profes-

sional applications.

• 

Make  certain  that  no  inflammable  liquids, 

water or metal objects enter the fixture.

• 

Do not dismantle or modify the fixture.

• 

All work must always be carried out by quali-

fied technical personnel. Contact the nearest 

sales  point  for  an  inspection  or  contact  the 

manufacturer directly.

• 

If the unit is to be put out of operation defini-

tively, take it to a local recycling  plant for a 

disposal which is not harmful to the environ-

ment.

SICUREZZA

Avvertenze generali

• 

I prodotti a cui questo manuale si riferisce sono 

conformi  alle  Direttive  della  Comunità  Euro-

pea e pertanto recano la sigla  .

• 

Il dispositivo funziona con pericolosa tensione 

di  rete  230V~.  Non  intervenire  mai  al  suo  in-

terno al di fuori delle operazioni descritte nel 

presente manuale; esiste il pericolo di una sca-

rica elettrica.

• 

È  obbligatorio  effettuare  il  collegamento  ad 

un impianto di alimentazione dotato di un’ef-

ficiente messa a terra (apparecchio di Classe I 

secondo  norma  EN  60598-1).  Si  raccomanda, 

inoltre, di proteggere le linee di alimentazione 

delle unità dai contatti indiretti e/o cortocircui-

ti verso massa tramite l’uso di interruttori diffe-

renziali opportunamente dimensionati.

• 

Le  operazioni  di  collegamento  alla  rete  di 

distribuzione  dell’energia  elettrica  devono 

essere  effettuate  da  un  installatore  elettrico 

qualificato. Verificare che frequenza e tensione 

della rete corrispondono alla frequenza ed alla 

tensione per cui l’unità è predisposta, indicate 

sulla targhetta dei dati elettrici. 

• 

L’unità  non  per  uso  domestico,  solo  per  uso 

professionale.

• 

Evitare che nell’unità penetrino liquidi infiam-

mabili, acqua o oggetti metallici.

• 

Non  smontare  e  non  apportare  modifiche 

all’unità.

• 

Tutti  gli  interventi  devono  essere  sempre  e 

solo effettuati da personale tecnico qualifica-

to. Rivolgersi al più vicino centro di assistenza 

tecnica autorizzato.

• 

Se si desidera eliminare il dispositivo definiti-

vamente,  consegnarlo  per  lo  smaltimento  ad 

un’istituzione locale per il riciclaggio.

WARNING!

Prima  di  effettuare  qualsiasi  operazione  con 
l’unità,  leggere  con  attenzione  questo  manuale 
e  conservarlo  accuratamente  per  riferimenti 
futuri.  Contiene  informazioni  importanti  riguardo 
l’installazione, l’uso e la manutenzione dell’unità.

ATTENZIONE!

Summary of Contents for Pro Audio AM6120

Page 1: ...E USER MANUAL IT EN AM6120 AM6260 AM6360 PA AMPLIFIERS AM6120 BASS TREBLE MIC 1 MIC 1 MIC 2 MIC 3 AUX 1 AUX 2 CH 1 OFF OFF OFF OFF OFF OFF CH 2 CH 3 CH 4 CH 5 CH 6 ZONE VOLUME MIXER POWER AMPLIFIER 17...

Page 2: ...nel presente manuale di istruzioni Tutte le revisioni e gli aggiornamenti sono disponibili nella sezione Manuali sul sito www musiclights it All rights reserved by Music Lights S r l No part of this...

Page 3: ...systems Warranty Sicurezza Avvertenze generali Attenzioni e precauzioni per l installazione Informazioni generali 1 Descrizione e specifiche tecniche 1 1 Introduzione 1 2 Caratteristiche tecniche 1 3...

Page 4: ...isposal which is not harmful to the environ ment SICUREZZA Avvertenze generali I prodotti a cui questo manuale si riferisce sono conformi alle Direttive della Comunit Euro pea e pertanto recano la sig...

Page 5: ...izia disconnettere l unit dalla rete di alimentazione Per la pulizia del prodotto non usare solventi tipo acetone o alcool per non danneggiare la finitura esterna e le serigrafie dei pannelli Warnings...

Page 6: ...tavia ogni obbligo di risarcimento per danni diretti o indiretti even tualmente derivanti dalla difettosit GENERAL INFORMATION Shipments and claims The goods are sold ex works and always travel at the...

Page 7: ...ollo dei toni bassi e alti Sei zone con livello indipendente di uscita Controlli indipendenti per segnali in ingresso 2U 19 standard rack 1 DESCRIPTION ANDTECHNICAL SPECIFICATIONS 1 1 INTRODUCTION Stu...

Page 8: ...i di volume che regolano il livello di ciascuna zona 5 step volume OFF output a 0 step1 output a 6V step2 a 13V step3 a 25V step4 a 50V e step5 a 100V 1 MOUNTING HOLES for fixing the rack 2 HANDLES 3...

Page 9: ...la presa si trova il portafusibile 18 PRESE DIVENTILAZIONE aperture per uscita flusso d aria da non ostruire 10 MUTE CONTROL adjusts the automatic attenuator 11 6 3 mm JACK PLUG for Mic 2 and Mic 3 in...

Page 10: ...e dei segnali d ingresso con i relativi CONTROLLI DI LIVELLO 8 Portare i CONTROLLI DI LIVELLO 8 degli in gressi non utilizzati sullo zero Se necessario impostare i toni con controlli BASS TREBLE 7 2 I...

Page 11: ...OLLEGAMENTO ALTRA APPARECCHIATU RA AUDIO Il collegamento di altre apparecchiature audio ad esempio per avere la musica di sottofondo si pu effettuare utilizzando gli ingressi RCA AUX1 e AUX2 posti nel...

Page 12: ...eamp output 2 x RCA 4 16 Ohm on terminal board 6 zone out on terminal board preamp output 2 x RCA Frequency response 60 16000 Hz 3 dB 60 16000 Hz 3 dB 60 16000 Hz 3 dB Distortion THD 0 5 1kHz 0 5 1kHz...

Page 13: ...in base al tipo di altoparlanti e alle impedenze di ciascuno In prossimit degli al toparlanti sono riportate le corrette polarit Gli impianti a tensione costante utilizzano invece GENERAL CRITERIA FO...

Page 14: ...utilizzare sempre cavi con conduttori intrecciati 16 Ohm 120W 4 Ohm 30W 4 Ohm 30W 4 Ohm 30W 4 Ohm 30W SERIES CONNECTION 16 Ohm 30W 16 Ohm 30W 16 Ohm 30W 16 Ohm 30W 4 Ohm 120W PARALLEL CONNECTION 16 Oh...