Section 2b
– INSTALLATION
Cell and Manifold Installation
Your MURSATT GEN-R-8 System is adaptable for use with the 15 blade (CC15) cell. The manifold must be located as the
last accessory in the
POOL RETURN LINE
only. For special plumbing configurations, please contact your representative for
assistance in locating the manifold.
Standard Manifold Assembly:
Bypass flow rate should be set at 94.5 lpm (25 gpm
)
.
Tri-Sensor Assembly
Cell # CC-15
13.8 kpa
Ball Valve #2
(2 lb) Spring
Check Valve
To Pool Return
For other plumbing configurations, please contact your representative for assistance.
Verification of Flow Switch Protection:
It is important to
ANNUALLY
inspect and verify the safe and proper operation of the Tri-sensor’s Flow Switch protection
device. We recommend following this procedure to verify that the flow switch is working as designed, which is to halt power
from being sent to the cell in the presence of insufficient flow. A defective Flow Switch could cause serious personal and/or
equipment damage.
To test, turn the output dial to “0%”.
Slowly, throttle or close ball valve #1 until flow to the cell(s) is reduced to less
than 15 gallons per minute. DO NOT COMPLETELY CLOSE VALVE #1! Within a matter of ONE (1) TO TWO (2)
seconds, this flow obstruction should be indicated on the digital display and activate a red flashing “CHECK SYSTEM”
light. As soon as this protection feature has been verified as functioning properly, re-establish flow to the cell(s) by
returning ball valve #1 to its original flow setting. The system should IMMEDIATELY resume normal operation. If
the flow switch protection is NOT working properly, turn AC power off to the entire system IMMEDIATELY and
consult your representative or Authorized Service Centre.
Ball Valve #1