4.3.2 Configure Output Channels
The following CAN message also configures the outputs in two groups.
Configure Output Channels is a message sent to the PDM to set up the high-current output channels as a single
high-side output or as an H-bridge pair. It also sets the current limit and reset behavior. Depending on the
output configuration identifier, the message applies to either output channels 1-6 or 7-12 respectively.
Note:
When channels are set to H-bridge pair, they are paired
consecutively (i.e. 1 and 2, 3 and 4, etc.).
Transmission Repetition
On change of state (at least one time, < 1 sec)
Data Length
8 bytes
Data Page
0
PDU Format (PF)
239
Proprietary A, PDU1 format
PDU Specific (PS)
30 (1Eh) or as set
DA (Source Address of the PDM)
Priority
5
Parameter Group Number
61184 (EF00h)
Start Position Length
Parameter Name
Reference
1
1 byte
Output Channel Group Identifier
2.5
4 bits
Current Limit (Output Channel 1 or 7)
2.3
2 bits
Feedback Type (Output Channel 1 or 7)
2.2
1 bit
Automatic Reset (Output Channel 1 or 7)
2.1
1 bit
High-Side or H-Bridge (Output Channel 1 or 7)
3.5
4 bits
Current Limit (Output Channel 2 or 8)
3.3
2 bits
Feedback Type (Output Channel 2 or 8)
3.2
1 bit
Automatic Reset (Output Channel 2 or 8)
3.1
1 bit
High-Side or H-Bridge (Output Channel 2 or 8)
4.5
4 bits
Current Limit (Output Channel 3 or 9)
4.3
2 bits
Feedback Type (Output Channel 3 or 9)
4.2
1 bit
Automatic Reset (Output Channel 3 or 9)
4.1
1 bit
High-Side or H-Bridge (Output Channel 3 or 9)
5.5
4 bits
Current Limit (Output Channel 4 or 10)
5.3
2 bits
Feedback Type (Output Channel 4 or 10)
5.2
1 bit
Automatic Reset (Output Channel 4 or 10)
5.1
1 bit
High-Side or H-Bridge (Output Channel 4 or 10)