Section 80
00-02-0829
2018-02-26
-
18 -
4.2 Naming and Numbering Conventions
The byte/bit order is represented in the following figure. Bit 1 is the least significant bit (lsb)
and Bit 8 is the most significant bit (msb). Byte 1 is the transmitted first and Byte 8 is last (i.e.
sequential).
The structures are defined for each type of configuration, control, feedback and diagnostic
message.
The following example message structure closely follows the SAE J1939 PGN convention.
The message must contain 8 bytes.
Example Message
Data Length
8 bytes
Start Position Length
Parameter Name
Reference
1
1 byte
Feedback and Diagnostics Identifier
2.7
2 bits
Digital Input 4
2.5
2 bits
Digital Input 3
2.3
2 bits
Digital Input 2
2.1
2 bits
Digital Input 1
3.7
2 bits
Digital Input 8
3.5
2 bits
Digital Input 7
3.3
2 bits
Digital Input 6
3.1
2 bits
Digital Input 5
4.7
2 bits
Digital Input 12
4.5
2 bits
Digital Input 11
4.3
2 bits
Digital Input 10
4.1
2 bits
Digital Input 9
5
2 bytes
Analog Input 1
7
2 bytes
Analog Input 2