background image

 
 

Warranty

 - A limited warranty on materials and workmanship is given with this FW Murphy product.  A copy of the warranty 

may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm 

 

 

Specifications 

PV101 Compatibility 

ƒ

 

Maximum supported: 

 

5 PVM Gages

 

ƒ

 

Maximum distance to last gage: 

 8.5 Meters

 

Power Supply Input Voltage 

ƒ

 

5V (4.5-5,.5.5 VDC minimum & maximum voltage) 

Power Supply Operating Current 

(@ 5 VDC) =

 

ƒ

 

PVM20, PVM35: 18 mA minimum; 80 mA maximum 

Backlight Maximum Current:  

60mA 

Input:  

RS485 MODBUS

®

 RTU data. 

Output:

  Analog Readout. 

Environmental 

Operating Temperature:  

-40 to 185

°

F (-40

°

 to 85

°

C) 

Storage Temperature:  

-67 to  185

°

F (-55

°

 to 85

°

C) 

Environmental Sealed Enclosure:   

ƒ

 

Sealing:  IP68, 

±

5 PSI (

±

 34.4 kPa) 

ƒ

 

Case and Clamp Material:  Polyester (PBT) 

ƒ

 

Lens Material:  Polycarbonate 

ƒ

 

Bezel Material:  Polyester (PBT) 

Dial:  

White numerals over black background 

Return-To-Zero Needle Movement: 

Not Available for PVM20 

models.

 

Indicating Pointer:

  Stepper motor operation with 270

°

 sweep 

Gage Accuracy:  

Better than 

±

 1.0% of scale 

Maximum Panel Thickness: 

 3/8 inch (9.6 mm)

  

Connectors: 

  

ƒ

 

Amp Mini Universal Mate-N-Lok 

ƒ

 

Amp Plug P/N:  172338-1 

ƒ

 

Amp Socket P/N:  171639-1 

Shipping Weight:  

1 Lb. (450 g.) 

Shipping Dimensions:   

ƒ

 

6 x 6 x 6 in. (153  x 153 x 153 mm) 

 

Typical Gage Dimensions 

 

 

 