Warranty
- A limited warranty on materials and workmanship is given with this FW Murphy product. A copy of the warranty
may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm
Specifications
PV101 Compatibility
Maximum supported:
5 PVM Gages
Maximum distance to last gage:
8.5 Meters
Power Supply Input Voltage
5V (4.5-5,.5.5 VDC minimum & maximum voltage)
Power Supply Operating Current
(@ 5 VDC) =
PVM20, PVM35: 18 mA minimum; 80 mA maximum
Backlight Maximum Current:
60mA
Input:
RS485 MODBUS
®
RTU data.
Output:
Analog Readout.
Environmental
Operating Temperature:
-40 to 185
°
F (-40
°
to 85
°
C)
Storage Temperature:
-67 to 185
°
F (-55
°
to 85
°
C)
Environmental Sealed Enclosure:
Sealing: IP68,
±
5 PSI (
±
34.4 kPa)
Case and Clamp Material: Polyester (PBT)
Lens Material: Polycarbonate
Bezel Material: Polyester (PBT)
Dial:
White numerals over black background
Return-To-Zero Needle Movement:
Not Available for PVM20
models.
Indicating Pointer:
Stepper motor operation with 270
°
sweep
Gage Accuracy:
Better than
±
1.0% of scale
Maximum Panel Thickness:
3/8 inch (9.6 mm)
Connectors:
Amp Mini Universal Mate-N-Lok
Amp Plug P/N: 172338-1
Amp Socket P/N: 171639-1
Shipping Weight:
1 Lb. (450 g.)
Shipping Dimensions:
6 x 6 x 6 in. (153 x 153 x 153 mm)
Typical Gage Dimensions