background image

00-02-0714 
2018-06-21 

Section 78 

 

PowerView

 - Model PV101-A-HAZ 

Instructions regarding ATEX Directive 94/9/EC 

The Murphy PV101-A-HAZ has been tested in compliance with EN 60079-0:2009 and EN 60079-15:2010. 

   II 3G    Ex nA T3 -

10˚C ≤ T

a

 

≤ +70˚C

 

To ensure compliance with this ATEX standard, the following must be adhered to: 

 

The display apparatus and associated harness must only be operated in the ambient temperature range 
 -

10˚C to +70˚C

 

 

 

No plugs shall be disconnected while the unit is energized. A warning label, of suitable material, stating 
‘WARNING – DO NOT SEPARATE WHILE ENERGIZED’ must remain adjacent to all connections throughout the 
unit’s service life. 

 

 

Only Murphy PV101-A-HAZ displays and Murphy-approved for ATEX plugs, sockets and harness connection 
points may be used as replacements. 

 

WARNING - SUBSTITUTION OF COMPONENTS MAY CAUSE 
IGNITION OF A COMBUSTIBLE OR FLAMMABLE ATMOSPHERE. 
Enovation Controls must be consulted before changing any 
component. 

 

Any harness replacement wiring must be Murphy (P/N 78000125) or Murphy-approved for ATEX. 

 

 

All wiring must be routed away from any sources of impact.  If this is not possible metal guarding must be 
used. 

 

 

Routinely inspect connections of plugs and sockets also ensuring all connections are secure in their 
positions. 

 

WARNING – POTENTIAL ELECTROSTATIC CHARGING HAZARD.  
Wipe only with a damp cloth, this includes the display unit and any 
of its shielding. 

 