Description

Murphy LR857 Lube Level Regulator maintains the crankcase oil
level of an engine, pump or compressor. Adjusted to the correct

run-

ning-oil-level

, the LR857 will replenish oil as it is used. An integral,

low-level switch will alarm and/or shutdown the equipment if supply
oil is lost and the equipment continues to use oil.

Specifications

Inlet Connection:

5/8 in. (16 mm) I.D. hose

Outlet Connection:

3/8 NPT

Snap-switch:

SPDT rating 10 A @ 125 VAC; 0.5 A @ 125 VDC; 

10 A @ 30 VDC

Conduit Connection:

1/2 NPT

Case:

Die cast aluminum

Lens:

Polycarbonate

Float:

Brass

Thumb-Valve™ Operation

As the equipment uses oil, the float falls, providing immediate level
compensation. At FULL position, the float holds the valve closed. If
the clean oil supply is depleted and oil level continues to fall, the low
level switch will operate an alarm or equipment shutdown.

Optional Mounting Brackets And Fittings Kit

Murphy offers two mounting brackets for the LR857. The (15000238)
Pipe Bracket Kit fits a 7/8 in. (22 mm) diameter pipe. The (15010224)
Universal Flange Kit allows various mounting methods. See
Dimensions section on reverse side.

The (15000420) Fittings Kit includes the following:

Quantity

Description

1

1/4 in. (6 mm) O.D. copper cane tube (vent connection)

1/4 in. (6 mm) tube x 1/4 male pipe fitting

1

1/2 in. (13 mm) I.D. hose fitting (outlet connection)

Flow Rates

Oil with 0.9 specific gravity @ 70°F (21°C)

Service Parts

Part Number

Description

15000159

Inlet Valve Assembly

15000100

Glass and Switch Assembly

15000161

Lid Assembly

15000941

Float Assembly (Brass-std)

15010224

Universal Flange Kit

15000238

Pipe Bracket Kit

15000420

Fittings Kit

Installation Instructions for 
LR857 Level Regulator

LR-9017N

Revised 03-05

Section 15

(00-02-0177)

WARNING

BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT

Disconnect all electrical power to the machine.

Make sure the machine cannot operate during installation.

Follow all safety warnings of the machine manufacturer.

Read and follow all installation instructions.

0       

05

10

15

20

25

0

Flow: 
USGPM

Head Pressure–Feet of Oil

Head Pressure–psi

0 psi

9.73 psi

0.2500 0.5000

Please read the following information before installing

A visual inspection of this product for damage during shipping is 

recommended before mounting. 

CRANKCASE MUST BE DRAINED BEFORE INSTALLATION.

GENERAL INFORMATION

COM. (white)

N.O. (black)

Low Level
Switch

LR857
Case

Float

Action

Oil Inlet

Thumb-Valve™

FULL

LOW

N.C. (red)

Simplified Drawing

*