background image

HD-96044N page 1 of 4

Installation and Operation Instructions for 
Dual Set Point Speed Switch

HD9063 Series 

HD-96044N

Revised 03-01

Section 20

(

00-02-0179)

Please read the following information before installing

.  

A visual inspection of this product for damage during shipping is recommended

before mounting. It is your responsibility to have a qualified person install this unit and make sure it conforms to NEC and local codes.

GENERAL INFORMATION

WARNING

BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT

Disconnect all electrical power to the machine.

Make sure the machine cannot operate during installation.

Follow all safety warnings of the machine manufacturer.

Read and follow all installation instructions.

Description

The HD9063 Series is a unitized two set point speed switch with
SPDT relay outputs. HD9063 is a PC-board configuration with
standoffs for mounting in a control panel or cabinet.

Models are available for crank disconnect/overspeed and for
underspeed/overspeed applications. Trip points can be field
adjusted on all models. LED’s next to the set point potentiometers
indicate that the trip point has been reached and the relay(s) have
operated. An overspeed test circuit is built-in; it will actuate the
output relay at a point below actual overspeed set point.

The

HD9063 

can disconnect the starter on automatic start engine

applications and shutdown the engine if an overspeed situation
occurs. Re-engagement of the starter is inhibited until RPM
returns virtually to zero.

HD9063-USOS 

models allow operation of control circuits

according to the speed of the driver or as a pre-alarm. 
Two separate adjustable speed switches are included on one 
common board.

Specifications

Power Supply:

Voltage: 

8-30 VDC

Maximum Current: 

150 mA

Frequency Signal:

Voltage, Magnetic Pickup Signal Models

• Minimum: 

0.35 Vrms 

• Maximum:

60 Vrms

Maximum Current, Magnetic Pickup Signal Models: 

4.8 µA.

Adjustment Range, Magnetic Pickup Signal Models

• HD9063 Model

Crank Disconnect: 

250-6,000 Hz

Overspeed: 

1,100-10,000 Hz 

• HD9063-USOS Model

Underspeed: 

200-5,800 Hz

Overspeed: 

1,100-10,000 Hz 

Reset Differential, Magnetic Pickup Signal Models

• HD9063 Model

Crank Disconnect: 

Dropout 160 Hz ± 5%

Overspeed:

200 Hz Differential

• HD9063-USOS Model

Underspeed: 

+5% of Set point Differential

Overspeed: 

155 Hz ± 10% Differential

Output: 

Relay Contact, SPDT, Resistive Load: 

(2) 5 A, 30 VDC

Adjustment:

(2) 270°–turn potentiometer

Temperature Range:

14 to 158°F (-10 to 70°C)

Reviews: