background image

FW Murphy – FuelCAN FLC300 installation instructions                                                           00-02-0663   revision A   26

th

 February 2010   p2/2 

Operation 

At each power up, FuelCAN checks all three inputs for  

an in-range sender resistance. If more than one sender is 

connected at power-up, FuelCAN prioritises input selection  

in the order 1 (Murphy), 2 then 3. 
Once FuelCAN has selected a valid input, it continues to  

use that input until the DC power supply is cycled. FuelCAN 

transmits fuel level data every 2 seconds. Data specification  

is otherwise as SAE J1939-71: 

PGN  65276 (00FEFC

16

Message data length  8 bytes 

Relevant byte  #2 (fuel level) 

Data page  0 

PDU format  254 

PDU specific  252 

Resolution  0.4%/bit gain, 0% offset 

Data range   0 to 100% 

If a sender failure (short or open circuit) occurs during 

operation, FuelCAN transmits fuel level data of value  

0xFE

16

 (indicating ‘measurement error’). 

If no valid sender is detected at power-up, FuelCAN transmits 

a value 0xFF

16

 (indicating ‘measurement not available’) and 

flashes its LED in a ‘heartbeat’ pattern (two short pulses, 

followed by a longer pause). J1939 message PGN65275  

also includes bytes for other parameters, including washer 

fluid level (byte #1), fuel filter differential pressure (byte #3), 

engine oil filter differential pressure (byte #4) and cargo 

ambient temperature (bytes #5/6). For each of these 

parameters, FuelCAN transmits a value 0xFF

16

 (indicating 

‘measurement not available’). 
LED operation is as follows:- 

LED pattern 

Status 

 f

f

o

 r

e

w

o

P

 f

f

O
Flashing 

(‘heartbeat’ pulse on) 

Power on, but all inputs open circuit 

(valid sender not detected). 

Flashing 

(50/50% on/off) 

Power on, valid sender input, but no 

CAN activity. 

  

d

n

a

 t

u

p

n

r

e

d

n

e

s

 

d

il

a

v

 ,

n

o

 r

e

w

o

P

 

n

O

CAN activity 

Maintenance and Warranty 

FuelCAN contains no user-serviceable parts. Maintenance is 

therefore limited to the following preventative checks: 

  Check that FuelCAN electrical connections are secure. 

  Check that the case is mounted securely, with vibration 

and environmental exposure minimised where possible. 

The case may be wiped with a clean, damp cloth. Do not 

use cleaning solvents. 

FuelCAN is supplied with a two year warranty on parts and 

workmanship. In the event of a fault or technical query,  

and before returning equipment, please contact your  

Murphy representative for technical support.

  

Electrical Connection & Mounting 

Electrical Connection 

FuelCAN connection is via 8 colour-coded flying leads  

(see diagram on page 1). 

RED: Power supply positive DC 

BLACK: Power supply negative DC 

Connect these wires to a smooth DC power supply in the range 

7 to 35 VDC. A 1 Amp anti-surge fuse is recommended in the 

positive DC line.

 

FuelCAN operates with negative earth/ground or fully insulated 

DC systems. 

DO NOT

 use FuelCAN with positive earth/ground 

systems. 

 

YELLOW: CANbus high 

GREEN: CANbus low 

Connect these wires to the engine’s CANbus, using the 

appropriate twisted-pair cable to J1939 specification. FuelCAN 

includes a non-removable 120 Ohm terminating resistor. 

BLACK: Sender common (negative DC) 

VIOLET: Sender input 1 (Murphy)

 

ORANGE: Sender input 2

 

WHITE: Sender input 3

 

For best measurement accuracy, use an insulated return  

(2-wire) resistive fuel level sender, e.g. (for input 1) Murphy 

ES2F series. Connect one sender terminal to the appropriate 

FuelCAN input lead (1, 2 or 3); connect the other sender 

terminal to FuelCAN’s Sender Common (black) wire. 
Where a 1-wire (negative DC/ground return) sender is used, 

connect the black (sender common) wire to battery negative. 

Mounting 

FuelCAN uses an epoxy-resin filled, polycarbonate case for high 

impact and environmental resistance. The case is compact  

and light enough for inclusion in (or tie-wrapping to) an engine 

wiring harness; or, using the actual product as a template, 

FuelCAN can be surface mounted via four M4 (0.15 in) holes 

(see diagram on page 1 for approximate dimensions). The case 

is sealed to IP65; the exposed flying leads must use connectors 

appropriate for the environmental sealing required. 

Operation and Maintenance 

 

 

In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time. 

MURPHY, the Murphy logo, are registered and/or common law trademarks of Murphy Industries, LLC. This document, including  

textual matter and illustrations, is copyright protected by Frank W Murphy Ltd., with all rights reserved. © 2010 Frank W Murphy Ltd. 

 

Reviews: