background image

 

Warranty

 - A limited warranty on materials and workmanship for one year is given with this FW Murphy product.  A copy of the 

warranty may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm 

 
 

Specifications 

Environmental 

ƒ

 Operating 

Temperature:-40

°

F to 185

°

F (-40

°

C and +85

°

C). 

ƒ

 

Humidity:  0-95% non-condensing 

ƒ

 

Vibration:  30 g’s (Mechanical stability) 

Power Requirements 

Murphy EVS-SB – Internal Battery Power 

ƒ

 

Battery power provided via 7.2V V lithium-Ion cell(s) 

ƒ

 

Open circuit maximum voltage of 10VDC. 

ƒ

 

Batter Life – 1 year under normal operation 

ƒ

 

Normal operation 10v> Vbat> 6.4v 

ƒ

 

Low battery mode:  5.0v< Vbat< 6.4v 

ƒ

 

System shutdown and alarm mode active below 5.0v 

Murphy EVS-A, EVS-S – External DC Power 

ƒ

 

External power:  8-32 VDC 

ƒ

 

Input Current:  100mA Max 

Product Accuracy 

ƒ

 

±

5% of full scale at 1.5 ips and 21 deg C. 

ƒ

 

±

5% Variation over temperature from 21 deg C, over 

operating range.. 

ƒ

 

Integration Stage End-to-End Noise:  <0.01 ips RMS 

Murphy EVS-S and EVS-A 

ƒ

 

±

5%, at Bandwidth of 6 to 500 Hz from 50Hz calibration 

point 

ƒ

 

±

3dB at Bandwidth of 3 to 875 Hz, worst case 

Murphy EVS-SB 

ƒ

 

±

5%, at Bandwidth of 6 to 350 Hz from 50Hz calibration 

point 

ƒ

 

±

3dB at Bandwidth of 3 to 875 Hz, worst case 

Trigger Feature 

ƒ

 

Trigger level between 0.1 and 1.5 inches per second (ips) 
Peak 

ƒ

 

Trigger set with single turn adjustable PC board mount 
potentiometer 

ƒ

 

PC board marked with 15 marks corresponding to 0.1 to 1.5 
in 0.1 increments 

Time Delay Feature 

ƒ

 

Adjustable from 0 to 10 seconds 

ƒ

 

Set with adjustable single turn PC board mount 
potentiometer 

ƒ

 

PC board marked with 11 marks corresponding to 0 to 10 
seconds in 1 second intervals 

Output 

ƒ

 

Normally-Open and Normally-Closed outputs simultaneously 
available 

ƒ

 

Open-collector outputs sink to Common Ground 

ƒ

 

50 mA sink capacity 

ƒ

 

Input voltage:  40 VDC maximum 

ƒ

 

Switch output is selectable for latched or non-latch 
configurations.  Reset accomplished by reset pushbutton or 
external contact closure when in latch mode. 

ƒ

 

Shutdown Alarm activated on power loss 

LED Outputs 

Alarm LED output 

ƒ

 

Red LED  

ƒ

 

LED strobing for first 5 minutes after entering Alarm mode 

ƒ

 

Flashing thereafter until Reset activated 

ƒ

 

Strobe rate:  2mSec on, every 0.5 

±

0.25 seconds 

ƒ

 

Flash rate:  2mSec on, every 6 

±

1 seconds 

Power LED output 

ƒ

 Green 

LED 

ƒ

 

Flash Duration:  2mSec 

Murphy EVS-S and EVS-A 

ƒ

 

Flash once every 6 

±

1 seconds 

Murphy EVS-SB 

ƒ

 

Battery status “Normal”: Flash once every 6 

±

1 seconds 

 

Battery in “Low-Battery” range:  Flash once every 12

±

seconds 

4-20mA output (EVS-A only) 

ƒ

 

Power obtained from power supply 

ƒ

 

Loop Resistance:  600 ohms max at 24 V and 20mA. 

ƒ

 

Current loop accuracy 

±

5% from internal setpoint 

ƒ

 

20 ma corresponds to 1.5 ips Peak 

ƒ

 

4 ma corresponds to 0 ips Peak 

Reset 

ƒ

 

Local reset switch w/momentary contact 

ƒ

 

External reset:  Available via header and will require an 
external relay or pushbutton contact to ground to activate the 
reset. 

ƒ

 

Activation Period:  Reset must be active for 0.5 sec. 
minimum to reset the switch. 

Circuit Functional blocks 

ƒ

 

Charge Amp interface 
- The input Transducer is an integrated PZT element for 
measuring acceleration with an internal charge converter. 
- Maximum G level of 13 g’s at 500hz 

ƒ

 Bandpass 

Filter 

- Frequency response dependent on model number (refer to 
“Product Accuracy”) 

ƒ

 Integration 

- Integration to convert from G to IPS peak 

Approvals 

ƒ

 

Hazardous Area approvals applied for.  (refer to “Product 
Table”) 

 NMEA 

Product Dimensions and Sensitivity Axis 

 