Warranty
- A limited warranty on materials and workmanship for one year is given with this FW Murphy product. A copy of the
warranty may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm
Specifications
Environmental
Operating
Temperature:-40
°
F to 185
°
F (-40
°
C and +85
°
C).
Humidity: 0-95% non-condensing
Vibration: 30 g’s (Mechanical stability)
Power Requirements
Murphy EVS-SB – Internal Battery Power
Battery power provided via 7.2V V lithium-Ion cell(s)
Open circuit maximum voltage of 10VDC.
Batter Life – 1 year under normal operation
Normal operation 10v> Vbat> 6.4v
Low battery mode: 5.0v< Vbat< 6.4v
System shutdown and alarm mode active below 5.0v
Murphy EVS-A, EVS-S – External DC Power
External power: 8-32 VDC
Input Current: 100mA Max
Product Accuracy
±
5% of full scale at 1.5 ips and 21 deg C.
±
5% Variation over temperature from 21 deg C, over
operating range..
Integration Stage End-to-End Noise: <0.01 ips RMS
Murphy EVS-S and EVS-A
±
5%, at Bandwidth of 6 to 500 Hz from 50Hz calibration
point
±
3dB at Bandwidth of 3 to 875 Hz, worst case
Murphy EVS-SB
±
5%, at Bandwidth of 6 to 350 Hz from 50Hz calibration
point
±
3dB at Bandwidth of 3 to 875 Hz, worst case
Trigger Feature
Trigger level between 0.1 and 1.5 inches per second (ips)
Peak
Trigger set with single turn adjustable PC board mount
potentiometer
PC board marked with 15 marks corresponding to 0.1 to 1.5
in 0.1 increments
Time Delay Feature
Adjustable from 0 to 10 seconds
Set with adjustable single turn PC board mount
potentiometer
PC board marked with 11 marks corresponding to 0 to 10
seconds in 1 second intervals
Output
Normally-Open and Normally-Closed outputs simultaneously
available
Open-collector outputs sink to Common Ground
50 mA sink capacity
Input voltage: 40 VDC maximum
Switch output is selectable for latched or non-latch
configurations. Reset accomplished by reset pushbutton or
external contact closure when in latch mode.
Shutdown Alarm activated on power loss
LED Outputs
Alarm LED output
Red LED
LED strobing for first 5 minutes after entering Alarm mode
Flashing thereafter until Reset activated
Strobe rate: 2mSec on, every 0.5
±
0.25 seconds
Flash rate: 2mSec on, every 6
±
1 seconds
Power LED output
Green
LED
Flash Duration: 2mSec
Murphy EVS-S and EVS-A
Flash once every 6
±
1 seconds
Murphy EVS-SB
Battery status “Normal”: Flash once every 6
±
1 seconds
Battery in “Low-Battery” range: Flash once every 12
±
1
seconds
4-20mA output (EVS-A only)
Power obtained from power supply
Loop Resistance: 600 ohms max at 24 V and 20mA.
Current loop accuracy
±
5% from internal setpoint
20 ma corresponds to 1.5 ips Peak
4 ma corresponds to 0 ips Peak
Reset
Local reset switch w/momentary contact
External reset: Available via header and will require an
external relay or pushbutton contact to ground to activate the
reset.
Activation Period: Reset must be active for 0.5 sec.
minimum to reset the switch.
Circuit Functional blocks
Charge Amp interface
- The input Transducer is an integrated PZT element for
measuring acceleration with an internal charge converter.
- Maximum G level of 13 g’s at 500hz
Bandpass
Filter
- Frequency response dependent on model number (refer to
“Product Accuracy”)
Integration
- Integration to convert from G to IPS peak
Approvals
Hazardous Area approvals applied for. (refer to “Product
Table”)
NMEA
4
Product Dimensions and Sensitivity Axis