M25 and M50 Series

Instant Response to Shut Off Signal

Positive Valve Closure

Vents Gases Trapped After Shutdown

Explosion-proof Models Available

Models Available for Magneto, 
CD Ignition or 12/24 VDC

Normally Energized Model Available

Description

These fuel shutoff valves are semi-automatic
devices for shutdown of natural gas fueled
engines. The valve is opened manually and closes
when the electromagnet is energized and trips the
latch. The valve can be closed manually by turning
the valve’s disconnect knob. A normally energized
model is available that holds the valve open elec-
trically and closes when the coil is de-energized. A
vent in the valve body relieves trapped gas when
the valve closes. A pop-out indicator button
informs you when the valve is open or closed.  

The valve’s tripping power is provided by an
engine ignition system or battery. Models are avail-
able for magneto, CD ignition or 12/24 V battery. 

The 

M2582  is a 1 inch (25 mm) valve

with 1

NPT connections. It has one SPDT snap-switch.
The valve body is made of sandcast aluminum. It
does not include the open/close indicator button.

M5081 is a 2 inch (51 mm) valve

with 2 NPT

connections. It has 

two

SPDT snap-switches.

The valve body is available in sandcast alu-
minum or cast steel (optional). 

M5081FS

is the same as the M5081 but has a

normally energized circuit. This circuit allows
the valve to be held open electrically and close
by interruption of the coil’s power circuit. 

A

manual trip knob is not available on this model.

An optional 2 in. (51 mm) steel flange pipe con-
nection is available for M5081 and M5081FS

steel body

models (see Dimensions page 3).

Specifications

Valve Body:

Sandcast aluminum, painted  

red (corrosion resistance). Optional cast 
steel available for M5081 and M5081FS 
models only.

Valve Seat:

Buna-N

Maximum Pressure Rating:

• M2582: 

80 psig (552 kPa) [5.52 bar]

• M5081: 

100 psig (689 kPa) [6.89 bar]

• M5081FS: 

100 psig (689 kPa) [6.89 bar]

Coil Rating:

Intermittent duty; coil 

type must match power source; 

• CD ignition coil resistance: 

72 Ω

CD primary voltage:

1.38 to 3.8 A 

• M5081FS model: Energized to run 

(continuous-duty coil) coil resistance:

12 Volt model:

33 Ω (0.36 A)

24 Volt model:

136 Ω (0.17 A)

• Magneto ignition coil resistance:

0.5 Ω

• Magneto primary voltage: 

1 to 5 A

• Battery coil resistance : 

7 Ω

12 or 24 VDC:

1.2 to 2.4 A

Wiring (See 

Internal Wiring

page 2):

• M2582: 

Wire leads

• M5081 and M5081FS: 

Terminal blocks

Snap-switch Rating:

5 A @ 480 VAC

Laboratory Approval:

CSA listed for Class I,

Groups C and D Hazardous Locations. 5 amps
maximum; intermittent duty; models M5081 and
M5081-CD engine ignition powered, and model
M5081-B, 12 or 24 VAC or VDC; switch con-
tacts rated 5 A @ 480 VAC maximum. 

Options and Accessories

Diode Package (65010065)

The Murphy 202 V diode package is designed to
allow the fuel shutoff valve to be used with dual
Magneto Ignition systems. Sold separately (see
How to Order).

Magnetic Switch Adapter 

As ignition systems wear from usage their power
output becomes less and less. Ignition may not
have the capacity to reliably trip the fuel valve.
Therefore, the use of a Magnetic Switch Adapter
for 

CD ignition systems

is recommended. The

adapter stores energy from the CD ignition to
trip the fuel valve. Three models are available:

65020126:

For Negative Ground CD Ignitions

up to 240 VDC

65020127:

For Positive Ground CD Ignitions up

to 450 VDC

65020155:

For Negative Ground CD Ignitions

240 VDC to 450 VDC

Warranty

A limited warranty on materials and workmanship
is given with this FW Murphy product. A copy of
the warranty may be viewed or printed by going to
www.fwmurphy.com/support/warranty.htm

Model M5081

MV-94134B

Revised 07-99

Catalog Section 55

(00-02-0124)

Electromechanical 
Fuel Shutoff Valves

Summary of Contents for Electromechanical Fuel Shutoff Valves M25

Page 1: ... M5081 and M5081FS models only Valve Seat Buna N Maximum Pressure Rating M2582 80 psig 552 kPa 5 52 bar M5081 100 psig 689 kPa 6 89 bar M5081FS 100 psig 689 kPa 6 89 bar Coil Rating Intermittent duty coil type must match power source CD ignition coil resistance 72 Ω CD primary voltage 1 38 to 3 8 A M5081FS model Energized to run continuous duty coil coil resistance 12 Volt model 33 Ω 0 36 A 24 Vol...

Page 2: ... o z 2 8 k g 10 psig 69 kPa 69 bar 20 psig 138 kPa 1 38 bar 30 psig 207 kPa 2 07 bar M2582 M5081 and M5081FS M2582 M5081 and M5081FS Inches water column p drop across valve Millimeters water column in brackets Standard cubic feet per hour Cubic meters per hour in brackets Inches water column p drop across valve Millimeters water column in brackets Standard cubic feet per hour Cubic meters per hour...

Page 3: ... Plug 1 2 NPT 2 NPT 2 places 3 in 76 mm 1 2 NPT Conduit Connection 2 plcs Valve Open Close Indicator Button Latching Handle latches valve open Manual Disconnect knob trips valve M5081 only 14 25 64 to 14 29 64 in 366 367 mm 3 4 in 19 mm dia 4 places each end equally spaced on a 4 3 4 in 121 mm b c bolt circle 45 3 5 8 in 92 mm diameter 2 in 51 mm dia 2 places 150 RF raised face pipe flange M5081 a...

Page 4: ...096 55000097 55000137 55000102 55000102 55000095 55000144 55000074 55000118 55000158 55000159 55000126 55000127 55000080 Handle and Latch Kit Handle and latch kit Handle kit Manual DIsconnect Assembly 55000098 55000072 55000160 Snap switch Assembly 5500 0138 55000138 Close Open Indicator Assembly 55000093 55000075 55000135 Stem and Seat Kit 55000194 24V 55000143 55000132 55000131 55000132 65020126...

Reviews: