Specifications
Power Supply
•
Operating voltage:
•
12V range (link L2-in place) 7-16 VDC
•
24V range (link L2-cut) 19-30 VDC
•
Current consumption:
•
CDV100F: 25mA typical
•
CDV300R: 50mA, typical (2 LEDs lit)
Inputs
•
CANbus:
•
SAE J1939 protocol, Input fitted with 120 Ohm terminating resistor, removable by cutting link L1.
Outputs
•
Oil pressure gage, coolant temperature gage
•
Link selectable for Murphy, VDO or Datcon electric gages
•
Tachometer
•
Pulsed DC, approximately 121 Hz @ 1500 RPM
General
•
Overall dimensions (W x H x D)
•
Case: 2.7x3.8x0.9 inch (68x96x22mm) (allow 2 inches (50mm) depth with connector)
•
Weight: approximately .18 lbs (80g)
•
Environmental sealing
•
IP60
•
CDV300R: IP65 from front with CDVG gasket (included)
•
Operating ambient temperature: -40
°
F to 185
°
F (-40
°
C to +85
°
C)
•
Storage temperature: -67
°
F to 221
°
F (-55
°
C to 105
°
C)
•
Operating Vibration: .02 lbs (10g) (5-2000 Hz)
•
Operating Shock: .11 lbs (50g) (3-axis)