![Murex Transarc 250 Instruction Manual And Spare Parts List Download Page 7](http://html.mh-extra.com/html/murex/transarc-250/transarc-250_instruction-manual-and-spare-parts-list_1857669007.webp)
-- 7 --
bh36d1ea
5.3
Mains power supply
Make sure that the welding power source is connected to the correct supply voltage
and that it is protected by the correct fuse rating. A protective earth connection must
be made in accordance with regulations.
Rating plate with supply connection data
5.3.1
Recommended fuse sizes and minimum cable area
Transarc 250
Mains voltage
400V
Mains cable area
mm
2
4 G 1.5
Phase current
I
1eff
8 A
Fuse
anti--surge
type C MCB
10 A
10 A
NOTE!
The cable area and fuse rating above comply with Swedish regulations. Use the welding power source
in accordance with the relevant national regulations.