Murex Tradesarc 150 Instruction Manual Download Page 23

-- 23 --

notes

NOTES

Summary of Contents for Tradesarc 150

Page 1: ...GB Valid for serial no 827 xxx xxxx 0460 813 074 090605 Tradesarc 150 Instruction manual and spare parts list ...

Page 2: ...RATION 7 6 1 PFC Power factor correction 7 6 2 Connections and control devices 7 6 3 Control panel 7 6 4 Connection of welding and return cable 8 6 5 Overheating protection 8 6 6 MMA welding 8 6 7 TIG welding 8 7 MAINTENANCE 9 7 1 Power source 9 7 2 Welding torch 9 8 FAULT TRACING 10 9 ORDERING SPARE PARTS 10 10 DISMANTLING AND SCRAPPING 10 DIAGRAM 12 SPARE PARTS LIST 15 ACCESSORIES 21 ...

Page 3: ...nted with the operation of the welding equipment Incorrect operation of the equipment may lead to hazardous situations which can result in injury to the operator and damage to the equipment 1 Anyone who uses the welding equipment must be familiar with S its operation S location of emergency stops S its function S relevant safety precautions S welding 2 The operator must ensure that S no unauthoriz...

Page 4: ...ding screen and filter lens and wear protective clothing S Protect bystanders with suitable screens or curtains FIRE HAZARD S Sparks spatter can cause fire Make sure therefore that there are no inflammable materials nearby NOISE Excessive noise can damage hearing S Protect your ears Use earmuffs or other hearing protection S Warn bystanders of the risk MALFUNCTION Call for expert assistance in the...

Page 5: ... 58 72 V Operating temperature 10 C 40 C Transportation temperature 20 C 55 C Constant sound pressure at no load 70 dB Dimensions l x b x h 418 x 188 x 208 mm Weight 7 9 Enclosure class IP 23 Application class Duty cycle The duty cycle refers to the time as a percentage of a ten minute period that you can weld at a cer tain load without overloading The duty cycle is valid for 40 C The duty cycle i...

Page 6: ...n Place the power source so that its cooling air inlets and outlets are not obstructed 5 2 Mains power supply Check that the welding power source is connected to the correct voltage and that the correct fuse size is used The standards for the country in question must be complied with as regards the mains cable area A protective earth connection must be made in accordance with regulations Rating pl...

Page 7: ...es against fluctuating mains voltage and makes it safer to use with a generator Tradesarc 150 can operate with extra long mains cables over 100 m giving you a very larger working radius 6 2 Connections and control devices 1 Connection MMA for return cable or welding cable TIG for return cable 4 Toggle switch for mains power supply 0 1 2 Control panel see under 6 3 5 Mains cable 3 Connection MMA co...

Page 8: ...25 MMA welding may also be referred to as welding with coated electrodes Striking the arc melts the electrode and its coating forms protective slag If when striking the arc the tip of the electrode is pressed against the metal it immedi ately melts and sticks to the metal rendering continued welding impossible Therefore the arc has to be struck in the same way that you would light a match Quickly ...

Page 9: ...ion CAUTION All guarantee undertakings from the supplier cease to apply if the customer himself attempts any work in the product during the guarantee period in order to rectify any faults WARNING The mains supply must be disconnected before cleaning 7 1 Power source Check regularly that the welding power source is not clogged with dirt How often and which cleaning methods apply depend on S the wel...

Page 10: ...performed by an authorized serviceman Use only original spare and wear parts Tradesarc 150 is designed and tested in accordance with the international and Europe an standard IEC EN 60974 1 EN 60974 10 It is the obligation of the service unit which has carried out the service or repair work to make sure that the product still conforms to the said standard 10 DISMANTLING AND SCRAPPING Welding equipm...

Page 11: ... 11 p ...

Page 12: ...Diagram 12 bh31e ...

Page 13: ... 13 bh31e ...

Page 14: ... 14 p ...

Page 15: ...0 Hz with MMA kit Spare parts are to be ordered through the nearest MUREX agency Kindly indicate type of unit serial number denominations and ordering numbers according to the spare parts list Maintenance and repair work should be performed by an experienced person and electrical work only by a trained electrician Use only recommended spare parts ...

Page 16: ...Screw MRT ground cutter M5x12 AA11 1 Front panel Included in item AA51 AA13 1 0460 690 001 Sticker Tradesarc 150 AA14 5 0366 588 001 Nut AA15 6 0469 381 002 Fast lock nut M5 AA16 1 0460 427 001 Bar plus AA17 1 0460 152 981 Cable set course AA18 2 0160 362 025 Connector OKC 50 Included in item AA51 XS1 XS2 AA19 2 0366 247 001 Nut AA20 2 0366 306 003 Spring washer Ø21 15x1 AA21 2 0468 497 001 Holder...

Page 17: ...Tradesarc 150 R0460 813 074 E090605 P20 17 bh33ma1 Tradesarc 150 ...

Page 18: ...ductor PFC 15L2 AB8 1 0194 158 003 Capacitor 1000 uF 450 V DC 15C1 AB9 0487 060 880 Secondary board 15AP2 AB10 1 Circuit board See item AB51 15AP1 AB11 1 Semiconductor module See item AB51 AB12 1 0468 030 880 Shunt 15RS1 AB13 1 0459 194 001 Busbar AB14 1 0467 801 002 Fan 24 V DC with cables and socket 15XS3 15EV1 SPARE PARTS SETS Item Qty Ordering no Denomination Notes AB50 1 0459 385 880 Diode mo...

Page 19: ...Tradesarc 150 R0460 813 074 E090605 P20 19 bh33mb1 Tradesarc 150 ...

Page 20: ...R0460 813 074 E090605 P20 20 paut ...

Page 21: ...0 Tradesarc 150 Accessories 21 bh33ma11 Strap 0460 265 001 Cable holder 2 pcs 0460 265 002 Shoulder strap 0460 265 003 Trolley for 5 10 litre gasbottle 0459 366 885 Welding cable kit Return cable kit 0700 006 898 0700 006 899 ...

Page 22: ... 22 notes NOTES ...

Page 23: ... 23 notes NOTES ...

Page 24: ...Murex Welding Products Ltd Hanover House Queensgate Britannia Road Waltham Cross Hertfordshire EN8 7TF England Please ensure that this Operating Manual is available to the user of the equipment ...

Reviews: