P E T F O U N T A I N
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
INSTALLATION INSTRUCTIONS FOR M-PM74 PET FOUNTAIN
Valve Body w/
Flange Collar
Brass Nut
Regulator
Retainer
Fiber Ring
Rubber Gasket
Retaining
Ring
Pushbutton
1/4" Push-In
Elbows
The water flow can be adjusted using a slotted
narrow blade screwdriver and turning clockwise to
increase flow and counterclockwise to decrease flow.
INCREASE
FLOW
DECREASE
FLOW
Ø3/16"
HOLE
SLOTTED
SCREWDRIVER
FLOW ADJUSTMENT
To ensure plumb installation, lay a bubble level on fountain
bowl and adjust using shims or washer until the unit is level.
To test operation of bubbler, depress activation pushbutton
and adjust flow rate as required and check all connections
for leaks.
All normal maintenance is done from above the ground.
v
Always shut off water supply when doing any
maintenance.
v
To remove pedestal mounted pushbutton
assembly,
remove access panel. From inside of the pedestal,
remove inlet and outlet lines from push-in ports of the
valve body. Using a spanner wrench remove pushbutton
and retaining ring.
v
To replace regulator,
use a spanner wrench to remove
the pushbutton and retaining ring from the flange collar.
Use a spanner wrench to remove retainer from the inside
of the flange collar. Remove regulator, insert new
regulator and align ports to new regulator with mating
ports of valve body then replace retaining ring.
v
Re-assemble in reverse order
. When replacing inlet
and out line ensure to insert supply line into valve port
labeled “IN”. Ensure that plastic line not kinked when
fountain is re-assembled.
MAINTENANCE
Once concrete has cured, drill 3/4” diameter by 2” deep
holes following the pattern shown in the mounting base
detail for the provided drop-in anchors. Using the anchor
setting tool, hammer the provided drop-in anchors into the
drilled holes. Align mounting points on the fountain to the
mounting anchors in the concrete and secure the fixture to
the slab using the provided mounting hardware.
Through access panel make up connections to fountain’s
3/8” OD (1/4” nominal) plain end supply inlet and 1-1/4” OD
close elbow waste outlet.
2"
WASTE OUTLET,
BY OTHERS
SUPPLY INLET,
BY OTHERS
16
3
8
" TYP
MOUNTING BASE DETAIL
3
7
8
"
Ø9
7
8
"
Please visit
www.murdockmfg.com
for most current specifications.
M-PM74
Page 2 of 3
Revised:
08/31/18
7020-971-001
MURDOCK MFG. •
15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
Member of