P E T F O U N T A I N
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
INSTALLATION INSTRUCTIONS FOR M-PM14 PET FOUNTAIN
Once concrete has cured, drill 3/4” diameter by 2” deep
holes following the pattern shown in the mounting base
detail for the provided drop-in anchors. Using the anchor
setting tool, hammer the provided drop-in anchors into the
drilled holes. Align mounting points on the fountain to the
mounting anchors in the concrete and secure the fixture to
the slab using the provided mounting hardware.
Through access panel make up connections to fountain’s
3/8” OD (1/4” nominal) plain end supply inlet and 1-1/4” OD
close elbow waste outlet.
To ensure plumb installation, lay a bubble level on fountain
bowl and adjust using shims or washers until the unit is level.
To test operation of bubbler, depress the activation
pushbutton and adjust flow rate as required and check all
connections for leaks.
MAINTENANCE
All normal maintenance is done from above the ground.
v
Always shut off water supply when doing any
maintenance.
v
To remove pedestal mounted pushbutton
assembly
remove access panel. From inside of the pedestal,
remove inlet and outlet lines from push-in ports of the
valve body. Using a spanner wrench remove pushbutton
and retaining ring.
v
To replace regulator
, use a spanner wrench to remove
pushbutton and retaining ring from the flange collar. Use a
spanner wrench to remove retainer from the inside of the
flange collar. Remove regulator, insert new regulator and
align ports to new regulator with mating ports of valve
body then replace retaining ring.
v
Re-assemble in reverse order
. When replacing inlet and
outlet line ensure to insert supply line into valve port
labeled “IN”. Ensure that plastic line is not kinked when
fountain is re-assembled.
Valve Body w/
Flange Collar
Brass Nut
Regulator
Retainer
Fiber Ring
Rubber Gasket
Retaining
Ring
Pushbutton
1/4" Push-In
Elbows
3
7
8
"
TYP
2"
5"
TYP
16
3
8
"
WASTE OUTLET
SUPPLY INLET
MOUNTING BASE DETAIL
Ø9
7
8
"
The water flow can be adjusted using a slotted
narrow blade screwdriver and turning clockwise to
increase flow and counterclockwise to decrease flow.
INCREASE
FLOW
DECREASE
FLOW
Ø3/16"
HOLE
SLOTTED
SCREWDRIVER
FLOW ADJUSTMENT
Please visit
www.murdockmfg.com
for most current specifications.
M-PM14
Page 2 of 3
Revised:
05/11/17
7020-204-001
MURDOCK MFG. •
15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
Member of